6.3 Page 2 Registers
6.3.1 Voltage Sag Duration (VSAGduration, V2SAGduration) Registers
Address: 0 (VSAGduration), 8 (V2SAGduration)
MSB
LSB
0
222 221 220 219 218 217 216 .....
26
25
24
23
22
21
20
Default = 0x000000
Voltage Sag Duration (VSAGduration, V2SAGduration) defines the number of instantaneous measurements utilized
to determine a sag event. Setting these register to zero will disable this feature. The value is represented in un-
signed notation. See Section 5.6 Sag and Fault Detect Feature on page 20
6.3.2 Current Fault Duration (ISAGduration, I2SAGduration) Registers
Address: 4 (ISAGduration), 12 (I2SAGduration)
MSB
LSB
0
222 221 220 219 218 217 216 .....
26
25
24
23
22
21
20
Default = 0x000000
Current Fault Duration (ISAGduration, I2SAGduration) defines the number of instantaneous measurements utilized
to determine a sag event. Setting these register to zero will disable this feature. The value is represented in un-
signed notation. See Section 5.6 Sag and Fault Detect Feature on page 20.
6.3.3 Voltage Sag Level (VSAGlevel, V2SAGLevel) Registers
Address: 1 (VSAGlevel), 9 (V2SAGlevel)
MSB
LSB
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
..... 2-18 2-19 2-20 2-21 2-22 2-23 2-24
Default = 0x000000
Voltage Sag Level (VSAGlevel), V2SAGlevel) defines the voltage level that the magnitude of input samples, aver-
aged over the sag duration, must fall below in order to register a sag condition. These value are represented in
unsigned notation and in the range of 0 VSAGlevel < 1.0 (0 V2SAGlevel < 1.0), with the binary point to the left
of the MSB. See Section 5.6 Sag and Fault Detect Feature on page 20.
6.3.4 Current Fault Level (ISAGlevel, I2SAGlevel) Registers
Address: 5 (ISAGlevel), 13 (I2SAGlevel)
MSB
LSB
2-1
2-2
2-3
2-4
2-5
2-6
2-7
2-8
..... 2-18 2-19 2-20 2-21 2-22 2-23 2-24
Default = 0x000000
Current Fault Level (ISAGlevel, I2SAGlevel) defines the voltage level that the magnitude of input samples, aver-
aged over the fault duration, must fall below in order to register a fault condition. These value are represented
in unsigned notation and in the range of 0 ISAGlevel < 1.0 (0 I2SAGlevel < 1.0), with the binary point to the left
of the MSB. See Section 5.6 Sag and Fault Detect Feature on page 20.