CS5462
4.8 Basic Application Circuit
Configurations
Figure 9 shows the CS5462 configured to measure
power in a single-phase 2-wire system while oper-
ating in a single supply configuration. In this dia-
gram, the shunt resistor used to monitor the line
current is connected on the “Line” (hot) side of the
power mains. In most residential power metering
applications, the power meter’s current-sense
shunt resistor is intentionally placed on the hot side
of the power mains in order to detect a subscriber’s
attempt to steal power. In this type of shunt-resistor
configuration, the common-mode level of the
CS5462 must be referenced to the hot side of the
power line. This means that the common-mode po-
tential of the CS5462 will typically oscillate to very
high voltage levels, as well as very low voltage lev-
els, with respect to earth ground potential.
N 120 VAC L
500 Ω
470 nV
R2
R1
RV-
RI-
RSHUNT
RI+
500 Ω
+ 100 µF
CV+
CV-
CI-
CI+
0.1 µF
10 Ω
0.1 µF
14
AVGAN+D
9
VIN+
CVdiff
10
VIN-
15
IIN-
CIdiff
16
IIN+
3
VD+ / P7
NEG / P2
6
IGAIN 17
P3 20
CAL0 23
CAL1
5
FREQ 7
DGND / P1 4
22
EDEIR2 // P4
EE1O/ UP5T 21
18
FOUT / P6
XOUT 1
12
VREFIN
11 VREFOUT
24
XIN
CPUCLK 2
AVGAN-D
13
DGND
8
0.1 µF
Jumpers
for
Calibration,
Freq Select
and
Gain Select
Stepper
Motor
or
Mechanical
Counter
Figure 8. Typical Connection Diagram