CS5462
4. FUNCTIONAL DESCRIPTION
4.1 Programmable Gain Amplifier (PGA)
The CS5462 is equipped with a PGA on the current
channel. While the voltage channel is always set to
a 10x differential input voltage range (50 0mVP-P),
the current channel can be set to one of two differ-
ent input ranges. The maximum differential voltage
range on the current channel can be set to 10x
(500 mVP-P) and 50x (100 mVP-P).
The gain setting of the current channel’s PGA and
also the high pass filter option are selected by con-
necting the IGAIN pin to one of seven Program Se-
lect output pins. For all applications the IGAIN pin
must be tied to one and only one Program Select
pins. Figure 2 below shows the different options
that can be selected at startup. These seven differ-
IGAIN
P1 500mVP-P 10x no hpf
P2 100mVP-P 50x no hpf
P3 500mVP-P 10x hpf both
P4 100mVP-P 50x hpf both
P5 500mVP-P 10x hpf Ich
P6 100mVP-P 50x hpf Ich
P7 500mVP-P 10x hpf Vch
Figure 2. PGA Settings
ent options allow the CS5462’s PGA to be set up in
either 10x or 50x mode and enable or disable the
high pass filters in either of the voltage or the cur-
rent channels.
During Startup the CS5462 will scan the IGAIN in-
put pin and determine which Program Select out-
put it is connected to and then set the PGA and
HPF’s accordingly.
4.2 Pulse-Rate Output
E1 and E2 pins provide a simple interface from
which signed energy can be accumulated. E1 and
E2 can be set to either stepper motor mode or me-
chanical counter mode. The connectivity of the
FREQ pin determines the pulse output mode and
also the maximum frequency for E1 and E2. Figure
3 below describes the options for E1 and E2.
FREQ
P1 0.25 Hz / Step
P2 0.5 Hz / Step
P3
1 Hz / Step
P4
2 Hz / Step
P5
4 Hz / Step
P6 2 Hz / mech cnt
P7 16 Hz / mech cnt
Figure 3. Pulse Output Settings
For all applications FREQ must be connected to
one and only one of the Program Selects outputs
(P1 - P7). The frequency setting chosen using the
above table is equal to the set pulse rate frequency
if and only if a full-scale signal is applied to each
channel. As the input signal decreases the pulse
rate and pulse width will decrease by a percentage
equal to the product of the percentages of full-
scale inputs across each channel. For example, if
if FREQ is connected to P5, the maximum pulse
output rate is 4 Hz. Assuming 500 mV is selected
as full scale on each channel, 400 mV is measured
on current and voltage channels. 400 mV is 80% of
full scale. Since power is the product of current and
voltage the pulse outputs will be 80% * 80% = 64%
of full scale. Since 4Hz is the set full scale output
rate, pulses should appear on E1 and E2 at a
64% * 4 Hz = 2.56 Hz rate.
4.2.1 Stepper Motor Format.
In stepper motor mode the CS5462 produces alter-
nating pulses on E1 and E2. This pulse format is
designed to directly drive a stepper motor. Each
pin produces active-low pulses with frequency de-
pendent pulse widths. The figure below shows the
frequency and corresponding pulse width for each
option.
FREQ
connected to:
P1
Frequency 0.25 Hz
Pulse W idth 250 ms
P2
0.5 Hz
250 ms
P3
1 Hz
250 ms
P4
2 Hz
250 ms
P5
4 Hz
125 ms
pulse width