C8051F360/1/2/3/4/5/6/7/8/9
SFR Definition 18.2. SMB0CN: SMBus Control
SFR Page: all pages
SFR Address: 0xC0
R
R
MASTER TXMODE
Bit7
Bit6
(bit addressable)
R/W
STA
Bit5
R/W
STO
Bit4
R
R
ACKRQ ARBLOST
Bit3
Bit2
R/W
ACK
Bit1
R/W
Reset Value
SI 00000000
Bit0
Bit 7:
Bit 6:
Bit 5:
Bit 4:
Bit 3:
Bit 2:
Bit 1:
Bit 0:
MASTER: SMBus Master/Slave Indicator.
This read-only bit indicates when the SMBus is operating as a master.
0: SMBus operating in Slave Mode.
1: SMBus operating in Master Mode.
TXMODE: SMBus Transmit Mode Indicator.
This read-only bit indicates when the SMBus is operating as a transmitter.
0: SMBus in Receiver Mode.
1: SMBus in Transmitter Mode.
STA: SMBus Start Flag.
Write:
0: No Start generated.
1: When operating as a master, a START condition is transmitted if the bus is free (If the bus
is not free, the START is transmitted after a STOP is received or a timeout is detected). If
STA is set by software as an active Master, a repeated START will be generated after the
next ACK cycle.
Read:
0: No Start or repeated Start detected.
1: Start or repeated Start detected.
STO: SMBus Stop Flag.
Write:
0: No STOP condition is transmitted.
1: Setting STO to logic ‘1’ causes a STOP condition to be transmitted after the next ACK
cycle. When the STOP condition is generated, hardware clears STO to logic ‘0’. If both
STA and STO are set, a STOP condition is transmitted followed by a START condition.
Read:
0: No Stop condition detected.
1: Stop condition detected (if in Slave Mode) or pending (if in Master Mode).
ACKRQ: SMBus Acknowledge Request
This read-only bit is set to logic ‘1’ when the SMBus has received a byte and needs the ACK
bit to be written with the correct ACK response value.
ARBLOST: SMBus Arbitration Lost Indicator.
This read-only bit is set to logic ‘1’ when the SMBus loses arbitration while operating as a
transmitter. A lost arbitration while a slave indicates a bus error condition.
ACK: SMBus Acknowledge Flag.
This bit defines the out-going ACK level and records incoming ACK levels. It should be writ-
ten each time a byte is received (when ACKRQ=1), or read after each byte is transmitted.
0: A "not acknowledge" has been received (if in Transmitter Mode) OR will be transmitted (if
in Receiver Mode).
1: An "acknowledge" has been received (if in Transmitter Mode) OR will be transmitted (if in
Receiver Mode).
SI: SMBus Interrupt Flag.
This bit is set by hardware under the conditions listed in Table 18.3. SI must be cleared by
software. While SI is set, SCL is held low and the SMBus is stalled.
210