STTH5R06D/FP/B/G
THERMAL RESISTANCES
Symbol
Rth (j-c) Junction to case
Parameter
TO-220AC / DPAK / D2PAK
TO-220FPAC
Value
3.0
5.5
Unit
°C/W
STATIC ELECTRICAL CHARACTERISTICS
Symbol
Parameter
Tests conditions
Min. Typ. Max. Unit
IR
Reverse leakage
current
VR = 600V
Tj = 25°C
Tj = 125°C
20
µA
25 250
VF
Forward voltage drop IF = 5 A
Tj = 25°C
2.9
V
Tj = 125°C
1.4 1.8
To evaluate the maximum conduction losses use the following equation :
P = 1.16 x IF(AV) + 0.128 IF2(RMS)
DYNAMIC ELECTRICAL CHARACTERISTICS
Symbol
Tests conditions
trr IF = 0.5 A Irr = 0.25 A IR = 1A Tj = 25°C
IF = 1 A dIF/dt = - 50 A/µs
VR = 30V
IRM VR = 400 V IF = 5A
dIF/dt = - 200A/µs
S factor
Tj = 125°C
Qrr
tfr
IF = 5 A dIF/dt = 40 A/µs
VFP
VFR = 1.1 x VFmax
Tj = 25°C
Min.
Typ. Max. Unit
25 ns
40
5.0 6.0 A
0.35
110
nC
150 ns
4.5 V
Fig. 1: Conduction losses versus average current.
P(W)
13
12
11
10
9
8
7
6
5
4
3
2
1
0
0
δ = 0.05 δ = 0.1 δ = 0.2
δ = 0.5
IF(av)(A)
1
2
3
4
5
δ=1
T
δ=tp/T
6
tp
7
Fig. 2: Forward voltage drop versus forward
current.
IFM(A)
50
45
40
35
Tj=125°C
(Maximum values)
30
25
Tj=125°C
(Typical values)
20
15
Tj=25°C
(Maximum values)
10
5
VFM(V)
0
0
1
2
3
4
5
6
2/8