Pin Description ACS4110 part 1.
Pin
Sym
6,38,
52,82,
85,94, VD+
105,139,
161,162
IO
Name
-
+ve power
supply
Description
Power supply, 4.75 - 5.25
Volts.
115
VA+
-
+ve power
supply
Power supply for Clock
Recovery PLL, 4.75 - 5.25
Volts.
5, 37,
51,81,
84,108,
122,123,
124,128,
130,138,
159,160
GND
- Ground
Power Supply
41
TPOS1
33
TPOS2
27
TPOS3
21
TPOS4
15
TPOS5
9
TPOS6
1
171
165
47
TPOS7
TPOS8
TPOS9
TPOS10
I
Transmit Data
Positive
Transmit channel 1-16,
corresponds to +ve in bipolar
signal.
55 TPOS11
61 TPOS12
67 TPOS13
73 TPOS14
79 TPOS15
154 TPOS16
42
TNEG1
34
TNEG2
28
TNEG3
22
TNEG4
16
TNEG5
10
TNEG6
2
172
166
48
TNEG7
TNEG8
TNEG9
TNEG10
I
Transmit Data
Negative
Transmit channel 1-16,
corresponds to -ve in bipolar
signal.
56 TNEG11
62 TNEG12
68 TNEG13
74 TNEG14
80 TNEG15
153 TNEG16
39
RPOS1
30
RPOS2
24
RPOS3
18
RPOS4
12
RPOS5
4
RPOS6
174
168
158
44
RPOS7
RPOS8
RPOS9
RPOS10
O
Receive Data
Positive
Receive channel 1-16,
corresponds to +ve in bipolar
signal.
50 RPOS11
58 RPOS12
64 RPOS13
70 RPOS14
76 RPOS15
87 RPOS16
Pin Description ACS4110 part 2.
Pin
Sym IO
Name
Description
36 RNEG1
31 RNEG2
25 RNEG3
19 RNEG4
13 RNEG5
7
RNEG6
175
169
163
45
RNEG7
RNEG8
RNEG9
RNEG10
O
Receive Data
Negative
Receive channel 1-16,
corresponds to -ve in bipolar
signal.
53 RNEG11
59 RNEG12
65 RNEG13
71 RNEG14
77 RNEG15
88 RNEG16
When DCD=1, then the
131
DCD
O
Data Carrier
Detect
communicating modems have
synchronised, and are
communicating.
Connect fundamental parallel
120
121
XTI/
XTO
-
System Clock
Crystal
resonance crystal with
appropriate padding capacitor
to GND.
129
PORB
I
Power On
Reset
Will initialise the device when
PORB= 0. PORB is normally
connected to an RC circuit so
that a POR is automatically
invoked on power-up. PORB=
1 for normal operation.
Transmit
156 TmCLK I/O maintenance
CLK
Transmit maintenance Clock.
samples TmD on edge selected
by TRSEL control.
Receive
155 RmCLK O maintenance
Clock
Receive maintenance Clock.
samples RmD on edge selected
by RESEL control..
When RESEL = 1,
RPOS/RNEG and RmD data is
116
RESEL
I
Receive Edge
Select
valid on the rising edge of
RCLK/RmCLK. When RESEL
= 0, the data is valid on the
falling edge of RCLK/RmCLK.
When TRSEL = 0,
TPOS/TNEG and TmD data is
104
TRSEL
I
Transmit Edge latched on the falling edge of
Select
TCLK/TmCLK. When TRSEL
=1, the data is latched on the
rising edge of TCLK/TmCLK.
95
TmD1
Transmit
I maintenance
Data
NRZ maintenance channel.
TmD is sampled on the
TmCLK clock edge defined by
TRSEL.
92
RmD2
Receive
O maintenance
Data
NRZ maintenance channel.
RmD is sampled on the
RmCLK clock edge defined by
RESEL.
37
ACS411CS PRE-RELEASE Issue 6.0 July 1999.