7/31/07
CS5560
RECOMMENDED OPERATING CONDITIONS
(VLR = 0V, see Note 19)
Parameter
Symbol
Min
Typ
Max
Single Analog Supply
DC Power Supplies:
(Note 19)
V1+
V1+
V2+
V2-
V1-
V1+
V2-
V2-
4.75
5.0
5.25
4.75
5.0
5.25
-
0
-
-
0
-
Dual Analog Supplies
DC Power Supplies:
(Note 19)
V1+
V1+
+2.375 +2.5 +2.625
V2+
V2-
+2.375 +2.5 +2.625
V1-
V1+
-2.375 -2.5 -2.625
V2-
V2-
-2.375 -2.5 -2.625
Analog Reference Voltage
(Note 20) VREF
[VREF+] – [VREF-]
2.4 4.096 4.2
19. The logic supply can be any value VL – VLR = +1.6 to +3.6 volts as long as VLR ≥ V2- and VL ≤ 3.6 V.
20. The differential voltage reference magnitude is constrained by the V1+ or V1- supply magnitude.
ABSOLUTE MAXIMUM RATINGS
(VLR = 0V)
Unit
V
V
V
V
V
V
V
V
V
Parameter
Symbol
Min
Typ
DC Power Supplies:
[V1+] – [V1-] (Note 21)
-
VL + [ |V1-| ] (Note 22)
-
0
-
0
-
Input Current, Any Pin Except Supplies
(Note 23)
IIN
-
-
Analog Input Voltage
(AIN and VREF pins) VINA (V1-) – 0.3 -
Digital Input Voltage
VIND VLR – 0.3 -
Storage Temperature
Tstg
-65
-
Notes: 21. V1+ = V2+; V1- = V2-
22. V1- = V2-
23. Transient currents of up to 100 mA will not cause SCR latch-up.
Max
Unit
5.5
V
6.3
V
±10
mA
(V1+) + 0.3 V
VL + 0.3
V
150
°C
WARNING: Operation beyond these limits may result in permanent damage to the device.
14