DESCRIPTION
The STPM01 is designed for effective measurement of active energy in a power line system using the Rogowski and/or Shunt principle. This device can be implemented as a single chip 1-phase energy meter or as a peripheral measurement in a microprocessor based 1-phase or 3-phase energy meter.
The STPM01 consists, essentially, of two parts: the analog part and the digital part. The former, is composed by preamplifier and 1st order ΣD AD converter blocks, Bandgap voltage reference, Lowdrop voltage regulator and a pair of DC buffer, the latter, is composed by system control, clock generator, hard wired DSP and SPI interface. There is also a OTP block, which is controlled through the SPI by means of a dedicated command set. The configured bits are used for testing, configuration and calibration purpose.
◾ INTEGRATED LINEAR VREGS TO SUPPLY
THE DIGITAL AND ANALOG CORES
◾ ADVANCED BICMOS TECHNOLOGY FOR
HIGH PERFORMANCE
◾ OTP FOR CALIBRATION AND
CONFIGURATION
◾ INTEGRATED OSCILLATOR WITH
EXTERNAL RESISTOR OR CRYSTAL
◾ MONITOR BOTH LIVE AND NEUTRAL FOR
TAMPER DETECTION
◾ SIGMA DELTA 1st ORDER CONVERTER
◾ POWER SUPPLY CURRENT LESS THAN
6mA
◾ SUPPORT 50 ÷ 60 Hz – IEC 62052-11,
IEC 62053-2X SPECIFICATION FOR CLASS
0.5 AC WATT METERS
◾ PRECISION VOLTAGE REFERENCE ON
CHIP: 1.25 V AND 30 ppm/°C MAX
◾ TSSOP20 PACKAGE