datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

AT89C51CC03C-RLTIM View Datasheet(PDF) - Atmel Corporation

Part Name
Description
MFG CO.
AT89C51CC03C-RLTIM
Atmel
Atmel Corporation 
AT89C51CC03C-RLTIM Datasheet PDF : 197 Pages
First Prev 171 172 173 174 175 176 177 178 179 180 Next Last
DC Parameters for A/D
Converter
AC Parameters
Explanation of the AC
Symbols
Figure 81. Clock Signal Waveform for ICC Tests in Active and Idle Modes
VCC-0.5V
0.45V
0.7VCC
0.2VCC-0.1
TCHCL
TCLCH
TCLCH = TCHCL = 5ns.
Table 117. DC Parameters for AD Converter in Precision Conversion
Symbol Parameter
Min
Typ(1),(2)
Max
Unit Test Conditions
AVin Analog input voltage
Vss- 0.2
Vref + 0.2 V
Rref Resistance between Vref and Vss
12
16
24
kΩ
Vref(3) Reference voltage
2.40
3.00
V
Cai Analog input Capacitance
60
pF During sampling
Rai Analog input Resistor
400
Ω During sampling
INL Integral non linearity
2
1
lsb
3
Automotive
DNL Differential non linearity
0.5
1
lsb
OE
Note:
Offset error
-2
2
lsb
1. Typicals are based on a limited number of samples and are not guaranteed.
2. For temperatures higher than 85°C, use standard conversion (8-bit only) and
PRS > 2.
3. VREF < VCC + 0.2V for temperatures higher than 85.
Each timing symbol has 5 characters. The first character is always a “T” (stands for
time). The other characters, depending on their positions, stand for the name of a signal
or the logical status of that signal. The following is a list of all the characters and what
they stand for.
Example: TAVLL = Time for Address Valid to ALE Low.
TLLPL = Time for ALE Low to PSEN Low.
TA = -40°C to +85°C; VSS = 0V; VCC = 3V to 5.5V; F = 0 to 40 MHz.
(Load Capacitance for port 0, ALE and PSEN = 60 pF; Load Capacitance for all other
outputs = 60 pF.)
Table 118, Table 121 and Table 124 give the description of each AC symbols.
Table 119, Table 123 and Table 125 give for each range the AC parameter.
Table 120, Table 123 and Table 126 give the frequency derating formula of the AC
parameter for each speed range description. To calculate each AC symbols: Take the x
value and use this value in the formula.
Example: TLLIV and 20 MHz, Standard clock.
x = 30 ns
T = 50 ns
TCCIV = 4T - x = 170 ns
172 AT89C51CC03
4182K–CAN–05/06

Share Link: 