3. CHARACTERISTIC AND SPECIFICATION TABLES
CS42L56
RECOMMENDED OPERATING CONDITIONS
GND = AGND = 0 V; all voltages with respect to ground.
DC Power Supply
Analog
Charge Pump
LDO Regulator for Digital
Serial/Control Port Interface
Ambient Temperature
Parameters
Symbol
(Note 1)
(Note 1)
Commercial - CNZ
VA
VCP
VLDO
VL
TA
Min
1.62
1.62
1.62
1.62
-40
Max Units
2.75
V
VA
V
2.75
V
3.63
V
+85
C
ABSOLUTE MAXIMUM RATINGS
GND = AGND = 0 V; all voltages with respect to ground.
Parameters
Symbol
DC Power Supply
Analog, Charge Pump, LDO VA, VCP, VLDO
Serial/Control Port Interface
VL
Input Current
External Voltage Applied to Analog Input
External Voltage Applied to Analog Output
External Voltage Applied to Digital Input
Ambient Operating Temperature (power applied)
Storage Temperature
(Note 2)
(Note 3)
(Note 4)
(Note 3)
Iin
VIN
VIN
VIND
TA
Tstg
Min
-0.3
-0.3
-
AGND-0.3
-VHPFILT - 0.3
-0.3
-50
-65
Max
3.0
4.0
±10
VA+0.3
+VHPFILT + 0.3
VL+ 0.3
+115
+150
Units
V
V
mA
V
V
V
°C
°C
WARNING: Operation at or beyond these limits may result in permanent damage to the device. Normal operation
is not guaranteed at these extremes.
Notes:
1.
2.
3.
4.
Due to the existence of parasitic body diodes between VCP and VA, current flows from VCP to VA when-
ever the VA power supply is lower than VCP. This causes a “back-powering” effect on the VA power
supply rails internal to the part; therefore, VA should be maintained at an equal or greater voltage than
VCP at all times. While “back-powering” does not have any adverse effects on device operation with
respect to performance and reliability, it does lead to extra power consumption and therefore should be
avoided.
Any pin except supplies. Transient currents of up to ±100 mA on the analog input pins will not cause
SCR latch-up.
The maximum over/under voltage is limited by the input current.
VHPFILT is specified in “DC Characteristics” on page 27.
ANALOG INPUT CHARACTERISTICS
Test Conditions (unless otherwise specified): Connections to the CS42L56 are shown in the “Typical Connection Diagrams” on
page 11; Input test signal is a 1 kHz sine wave through the passive input filter, PGA = 0 dB; All Supplies = VA;
GND = AGND = 0 V; TA = +25C; Measurement bandwidth is 20 Hz to 20 kHz; Sample Frequency = 48 kHz. Measurement sig-
nal path is AINxx to SDOUT.
Parameter
Analog In to ADC (PGA bypassed)
VA = 2.5 V
VA = 1.8 V
Min Typ Max Min Typ Max Unit
14