STTS2002
8
DC and AC parameters
DC and AC parameters
This section summarizes the operating measurement conditions, and the dc and ac
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 29. Designers should check that the operating conditions in their circuit match the
operating conditions when relying on the quoted parameters.
Table 29. Operating and AC measurement conditions
Parameter
Conditions
Unit
VDD supply voltage
Operating temperature
Input rise and fall times
Load capacitance
Input pulse voltages
Input and output timing reference voltages
2.3 to 3.6
V
–40 to 125
°C
≤ 50
ns
100
pf
0.2VDD to 0.8VDD
V
0.3VDD to 0.7VDD
V
Figure 15. AC measurement I/O waveform
Input levels
0.8 * VDD
0.2 * VDD
Input and output timing
reference levels
0.7 * VDD
0.3 * VDD
ai14011
Table 30. DC/AC characteristics - temperature sensor component with EEPROM
Sym
Description
Test condition(1)
Min Typ(2) Max Unit
VDD Supply voltage
IDD VDD supply current (no load)
IDD1 Shutdown mode supply current
IILI Input leakage current (SCL, SDA)
IILO Output leakage current
VPOR Power on Reset (POR) threshold
EEPROM active(3)
F = 400 kHz
EEPROM standby,
F = 400 kHz
EEPROM standby,
TS shutdown
VIN = VSS or VDD
VOUT = VSS or VDD,
SDA in Hi-Z
VDD falling edge:
DN package
2.3
3.3
3.6
V
0.4
2.0
mA
160
300
µA
3.0
5
µA
±5
µA
±5
µA
1.75
V
Doc ID 15389 Rev 5
41/52