STTS2002
Temperature sensor operation
Table 2. AC characteristics of STTS2002 for SMBus and I2C compatibility timings
Symbol
Parameter
Min Max Units
fSCL
tHIGH
tLOW(1)
tR(2)
tF(2)
tSU:DAT
tHD:DI
tHD:DAT
tSU:STA(3)
tHD:STA
SMBUS/I2C clock frequency
Clock high period
Clock low period
Clock/data rise time
Clock/data fall time
Data in setup time
Data in hold time
Data out hold time
Repeated start condition setup time
Hold time after (repeated) start condition. After this
period, the first clock cycle is generated.
10 400 kHz
600 –
ns
1300 –
ns
– 300 ns
20 300 ns
100 –
ns
0
–
ns
200 900 ns
600 –
ns
600 –
ns
tSU:STO Stop condition setup time
600 –
ns
tBUF
Bus free time between stop (P) and start (S) conditions 1300 –
ns
tW(4)
WRITE time for EEPROM
–
10 ms
ttimeout(5) Bus timeout (temperature sensor only)
25 35 ms
1. STTS2002 will not initiate clock stretching which is an I2C bus optional feature.
2. Guaranteed by design and characterization, not necessarily tested.
3. For a restart condition, or following a WRITE cycle.
4. This parameter reflects maximum WRITE time for EEPROM.
5. Bus timeout value supported depends on setting of TMOUT bit 6 in capability register.
Doc ID 15389 Rev 5
15/52