datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

STM32F030RCP6TR View Datasheet(PDF) - STMicroelectronics

Part Name
Description
MFG CO.
STM32F030RCP6TR Datasheet PDF : 91 Pages
First Prev 51 52 53 54 55 56 57 58 59 60 Next Last
STM32F030x4/x6/x8/xC
Electrical characteristics
Symbol
Table 40. Flash memory endurance and data retention
Parameter
Conditions
Min(1)
NEND Endurance
TA = -40 to +85 °C
1
tRET Data retention
1 kcycle(2) at TA = 85 °C
20
1. Data based on characterization results, not tested in production.
2. Cycling performed over the whole temperature range.
Unit
kcycle
Years
6.3.11
EMC characteristics
Susceptibility tests are performed on a sample basis during device characterization.
Functional EMS (electromagnetic susceptibility)
While a simple application is executed on the device (toggling 2 LEDs through I/O ports).
the device is stressed by two electromagnetic events until a failure occurs. The failure is
indicated by the LEDs:
Electrostatic discharge (ESD) (positive and negative) is applied to all device pins until
a functional disturbance occurs. This test is compliant with the IEC 61000-4-2 standard.
FTB: A Burst of Fast Transient voltage (positive and negative) is applied to VDD and
VSS through a 100 pF capacitor, until a functional disturbance occurs. This test is
compliant with the IEC 61000-4-4 standard.
A device reset allows normal operations to be resumed.
The test results are given in Table 41. They are based on the EMS levels and classes
defined in application note AN1709.
Table 41. EMS characteristics
Symbol
Parameter
Conditions
VFESD
Voltage limits to be applied on any I/O pin
to induce a functional disturbance
VDD = 3.3V, LQFP48, TA = +25 °C,
fHCLK = 48 MHz,
conforming to IEC 61000-4-2
Fast transient voltage burst limits to be VDD = 3.3V, LQFP48, TA = +25°C,
VEFTB applied through 100 pF on VDD and VSS fHCLK = 48 MHz,
pins to induce a functional disturbance conforming to IEC 61000-4-4
Level/
Class
3B
4B
Designing hardened software to avoid noise problems
EMC characterization and optimization are performed at component level with a typical
application environment and simplified MCU software. It should be noted that good EMC
performance is highly dependent on the user application and the software in particular.
Therefore it is recommended that the user applies EMC software optimization and
prequalification tests in relation with the EMC level requested for his application.
Software recommendations
DocID024849 Rev 3
57/91
74

Share Link: 