STM1404
DC and AC parameters
Table 7. Physical and environmental tamper detection levels
Sym
Parameter
Test
conditions(1)
Min
Typ
Max
Unit
VHV
Overvoltage trip level
4.0
4.2
4.4
V
VLV
Undervoltage trip level
1.9
2.0
2.1
V
SAL propagation delay time
VHV + 200 mV or
(after over/under voltage detection) VLV – 200 mV
25
50
µs
VHTP
Trip point for NH physical tamper
input pins (TP1 or TP3)
VOUT - 1.3(2)
VOUT - 0.3(2) V
VLTP
Trip point for NL physical tamper
input pins (TP2 or TP4)
0.3
1.0
V
SAL propagation delay time(3)
(after physical tamper pin
detection)
VHTP =
VOUT/VTPU;
VLTP = VSS
VDD = 3.6
30
50
µs
Physical tamper input (TPX) glitch
immunity
15
µs
TH
TL
THYST
Factory-programmed
Temperature hysteresis
IOUT = 0 mA
–5
80, 85, 95
+5
°C
–5
–25, –35
+5
°C
10
°C
1. Valid for ambient operating temperature: TA = –40 to 85°C; VCC = VLV to VHV (except where noted). All physical and
environmental tamper functions are operational across the full temperature alarm range for STM1404.
2. In the case of STM1404A, physical tamper input pins (TPX) are referenced to VOUT (pin 12). In the case of STM1404B or
C, TPX are referenced to VTPU pin (pin 9).
3. VCC = VRST (max) to 3.6 V
Figure 28. Temperature hysteresis
TH
THYST(High)
Temperature
THYST(Low)
TL
SAL
AI11147b
29/36