Table 12.
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxx x x x xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xx xx
xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxx xxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxx x x
xxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxx xxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxx
xxxxxxxxxxxxxxxxxxxxxxxxx xxxxxxxxxxxxxxxxxxxx xxx
Bus control sequence
Read Control Register performed by the master
Write Control Register performed by the master
Byte Status
read[1]
NBUSON BUSON NMYBUS MYBUS Byte
Action performed NBUSON[3] BUSON NMYBUS[3] MYBUS
written[1][2] to take mastership
Hex
Hex
0 bus off has control
0
0
0
0
4
bus on
x
1
x
0
1 bus off no control
0
0
0
1
4
bus on, take control
x
1
x
0
2 bus off no control
0
0
1
0
5
bus on, take control
x
1
x
1
3 bus off has control
0
0
1
1
5
bus on
x
1
x
1
4 bus on has control
0
1
0
0
-
no change
no write required
5 bus on no control
0
1
0
1
4
take control
x
1
x
0
6 bus on no control
0
1
1
0
5
take control
x
1
x
1
7 bus on has control
0
1
1
1
-
no change
no write required
8 bus on has control
1
0
0
0
-
no change
no write required
9 bus on no control
1
0
0
1
0
take control
x
0
x
0
A bus on no control
1
0
1
0
1
take control
x
0
x
1
B bus on has control
1
0
1
1
-
no change
no write required
C bus off has control
1
1
0
0
0
bus on
x
0
x
0
D bus off no control
1
1
0
1
0
bus on, take control
x
0
x
0
E bus off no control
1
1
1
0
1
bus on, take control
x
0
x
1
F bus off has control
1
1
1
1
1
bus on
x
0
x
1
[1] Only the 4 LSBs are shown.
[2] x0x0 in binary = 0, 2, 8 or A in hexadecimal
x0x1 in binary = 1, 3, 9 or B in hexadecimal
x1x0 in binary = 4, 6, C or E in hexadecimal
x1x1 in binary = 5, 7, D or F in hexadecimal
[3] x can be either ‘0’ or ‘1’ since those bits are read-only bits.