DC and AC parameters
9
DC and AC parameters
M50FLW040A, M50FLW040B
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics Tables that
follow, are derived from tests performed under the Measurement Conditions summarized in
Table 20, Table 21 and Table 22. Designers should check that the operating conditions in
their circuit match the operating conditions when relying on the quoted parameters.
Table 20. Operating conditions
Symbol
Parameter
Min.
Max.
VCC Supply Voltage
3.0
3.6
TA
Ambient Operating Temperature (Device Grade 5)
–20
85
Table 21. FWH/LPC interface AC measurement conditions
Parameter
Value
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
10
≤1.4
0.2 VCC and 0.6 VCC
0.4 VCC
Table 22. A/A Mux interface AC measurement conditions
Parameter
Value
Load Capacitance (CL)
Input Rise and Fall Times
Input Pulse Voltages
Input and Output Timing Ref. Voltages
30
≤10
0 to 3
1.5
Unit
V
°C
Unit
pF
ns
V
V
Unit
pF
ns
V
V
Figure 10. FWH/LPC interface AC measurement I/O waveforms
0.6 VCC
0.4 VCC
0.2 VCC
Input and Output AC Testing Waveform
40/64
IO < ILO
IO > ILO
IO < ILO
Output AC Tri-state Testing Waveform
AI03404