datasheetbank_Logo
Integrated circuits, Transistor, Semiconductors Search and Datasheet PDF Download Site

CS4385(2004) View Datasheet(PDF) - Cirrus Logic

Part Name
Description
MFG CO.
CS4385
(Rev.:2004)
Cirrus-Logic
Cirrus Logic 
CS4385 Datasheet PDF : 56 Pages
First Prev 41 42 43 44 45 46 47 48 49 50 Next Last
CS4385
5.6 Invert Control (address 06h)
7
INV_B4
0
6
INV_A4
0
5
INV_B3
0
4
INV_A3
0
3
INV_B2
0
2
INV_A2
0
5.6.1 INVERT SIGNAL POLARITY (INV_XX)
Function:
When set to 1, this bit inverts the signal polarity of channel xx.
When set to 0 (default), this function is disabled.
1
INV_B1
0
0
INV_A1
0
5.7 Group Control (address 07h)
7
Reserved
0
6
MUTEC
0
5
Reserved
1
4
P1_A=B
0
3
P2_A=B
0
2
P3_A=B
1
1
P4_A=B
0
0
SNGLVOL
0
5.7.1 MUTEC PIN CONTROL(MUTEC)
Default = 0
0 - Two Mute control signals
1 - Single mute control signal on MUTEC1
Function:
Selects how the internal mute signals are routed to the MUTEC1 and MUTEC234 pins. When set to
‘0’, a logical AND of DAC pair 1 mute control signals are output on MUTEC1 and a logical AND of the
mute control signals of DAC pairs 2, 3, and 4 are output on MUTEC234. When set to ‘1’, a logical AND
of all DAC pair mute control signals is output on the MUTEC1 pin, MUTEC234 will remain static. For
more information on the use of the mute control function see the MUTEC1 and MUTEC234 pins in
section 3.11.
5.7.2 CHANNEL A VOLUME = CHANNEL B VOLUME (PX_A=B)
Default = 0
0 - Disabled
1 - Enabled
Function:
The AOUTAx and AOUTBx volume levels are independently controlled by the A and the B Channel Vol-
ume Control Bytes when this function is disabled. The volume on both AOUTAx and AOUTBx are deter-
mined by the A Channel Attenuation and Volume Control Bytes (per A-B pair), and the B Channel Bytes
are ignored when this function is enabled.
5.7.3 SINGLE VOLUME CONTROL (SNGLVOL)
Default = 0
0 - Disabled
1 - Enabled
42
DS671A1

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]