C8051F91x-C8051F90x
SFR Definition 16.3. DC0MD: DC-DC Mode
Bit
7
6
5
4
3
2
1
0
Name
BYPFLG
BYPSEL[1:0]
PASDEN
Type R/W
R/W
R/W
R/W
R
R/W
R/W
Reset
0
0
0
0
Varies
0
0
0
SFR Page = 0xF; SFR Address = 0x94
Bit
Name
Function
7:4 Unused Unused.
Read = 0000b, Write = don’t care.
3 BYPFLG Bypass Indicator.
Indicates when the dc-dc converter is operating in bypass mode. Only available on
‘F912 and ‘F902 devices.
0: DC0 is not operating in bypass mode.
1: DC0 is operating in bypass mode.
2:1 BYPSEL[1:0] Bypass Mode Select.
Selects the bypass settings. Only available on ‘F912 and ‘F902 devices.
00: Bypass mode disabled (highest supply current when the input voltage exceeds
the programmed output voltage).
01: Bypass enabled (auto switch), dc-dc oscillator enabled (fast response time)
10: Bypass enabled (auto switch), dc-dc oscillator disabled (reduced supply current)
11: The dc-dc converter is forced into bypass mode (lowest supply current when the
input voltage exceeds the programmed output voltage).
0 PASDEN Passive Diode Mode Enable.
Passive external diode mode. Only available on ‘F912 and ‘F902 devices.
0: Passive diode mode disabled.
1: Passive diode mode enabled.
16.13. DC-DC Converter Specifications
See Table 4.16 on page 60 for a detailed listing of dc-dc converter specifications.
Rev. 1.0
169