C8051F91x-C8051F90x
SFR Definition 15.4. CRC0AUTO: CRC0 Automatic Control
Bit
7
6
5
4
3
2
1
0
Name AUTOEN CRCDONE
CRC0ST[5:0]
Type
R/W
R/W
Reset
0
1
0
0
0
0
0
0
SFR Page = 0xF; SFR Address = 0x96
Bit
Name
Function
7
AUTOEN Automatic CRC Calculation Enable.
When AUTOEN is set to 1, any write to CRC0CN will initiate an automatic CRC
starting at Flash sector CRC0ST and continuing for CRC0CNT sectors.
6 CRCDONE CRCDONE Automatic CRC Calculation Complete.
Set to 0 when a CRC calculation is in progress. Code execution is stopped during
a CRC calculation; therefore, reads from firmware will always return 1.
5:0 CRC0ST[5:0] Automatic CRC Calculation Starting Flash Sector.
These bits specify the Flash sector to start the automatic CRC calculation. The
starting address of the first Flash sector included in the automatic CRC calculation
is CRC0ST x Page Size.
Note: ‘F91x and ‘F90x devices have a page size of 512 bytes.
Rev. 1.0
157