STFPC311
8
Default status
Default status
8.1
Power-up default status
Table 4. Default states
S. N°
Functions
Default status
1
Display
OFF
2
Key-scan
ON
3
IR
) 4
Display mode
t(s 5
Display address
c 6
RC Protocol
du 7
LED
ro 8
Dimming
P 9
Hot Kets (IR and FP)
lete 10
Watchdog timer
ON
12 Seg/16Bit
00H
DC-5
OFF
1/16 Duty factor
Disabled
10s
bso 8.2
STANDBY status
- O The display remains ON during STANDBY only if the -20V is present. If the -20V is absent,
t(s) the display turns OFF. When the display wakes up from STANDBY and –20V is applied, the
display turns ON with previous value.
uc Switching off the display before entering the STANDBY state is recommended.
rod When the same display configuration command is sent, the display remains ON. When the
display configuration command is changed, the display is OFF.
Obsolete P Only hot key detection can wake the system up from STANDBY condition.
Doc ID 12324 Rev 2