ADC DIGITAL FILTER CHARACTERISTICS
CS42L56
Parameter (Note 11)
Frequency Response (20 Hz to 20 kHz)
Passband
Stopband
Stopband Attenuation
Total Group Delay
High-Pass Filter Characteristics (48 kHz Fs) (Note 12)
Passband
Frequency Response
Phase Deviation @ 20 Hz
Filter Settling Time (Note 13)
to -0.05 dB corner
to -3 dB corner
Min
-0.07
-
-
0.52
33
-
Typ
-
0.421
0.495
-
-
4.3/Fs
Max
+0.02
-
-
-
-
-
Unit
dB
Fs
Fs
Fs
dB
s
to -3.0 dB corner -
to -0.05 dB corner -
-
-
-
1.87
-
Hz
17.15
-
Hz
-
0.15 dB
5.3
-
Deg
105/Fs
-
s
Notes:
11. Response is clock-dependent and will scale with Fs. Note that the response plots (Figures 41 to Note 44
on page 90) have been normalized to Fs and can be denormalized by multiplying the X-axis scale by Fs.
HPF parameters are for Fs = 48 kHz.
12. Characteristics are based on the default setting in register “HPF Control (Address 1Bh)” on page 75.
13. Settling time decreases at higher corner frequency settings.
DS851F2
17