STV224XH/228XH/223XH - I²C BUS SELECTION
Reg.
Addr
(Hex)
Description
Data
Bits
d7 d6 d5 d4 d3 d2 d1 d0
Comments
06
PIF VCO Compen-
sation
1
X X X X X X X 0 0 = Optimized for PIF from 33.9 to 38.9 MHz
X X X X X X X 1 1 = Optimized for PIF 45.75 & 58.75 MHz
2 X X X X X 0 0 X 6.5 MHz sound selected.
Sound Standard
Selection
X X X X X 0 1 X 6.0 MHz sound selected.
X X X X X 1 0 X 5.5 MHz sound selected.
X X X X X 1 1 X 4.5 MHz sound selected.
AGC SIF time
constant (AM)
1 X X X X 0 X X X 0 = Auto Time constant.
X X X X 1 X X X 1 = Fast Time constant forced.
SAW filter switch 1 X X X 0 X X X X 0 = output low (0.4 V Max.).
output
X X X 1 X X X X 1 = output high (4 V Min.).
CVBS output
(from PIF circuit)
1
X X 0 X X X X X 0 = CVBS output enable.
X X 1 X X X X X 1 = CVBS output muted.
QSS/Inter-carrier
Application
1
X 0 X X X X X X 0 = QSS application, intercarrier filter OFF
X 1 X X X X X X 1 = Intercarrier application
Not to be used
1 0 XXXXXXX
6.3.6 Video Controls
Reg.
Addr
(Hex)
Description
Data
Bits
d7 d6 d5 d4 d3 d2 d1 d0
Comments
07
Contrast Control
6 X X 0 0 0 0 0 0 -24 dB gain (Min. contrast).
X X 1 1 1 1 1 1 0 dB gain (Max. contrast).
RGB Peak
Limitation
0 = APR, APR Threshold, tracked with contrast.
1 X 0 X X X X X X 1 = RGB Peak Limitation, threshold not tracked with
X 1 X X X X X X contrast.
Note: RGB Peak Limitation active when WR10 d0 =
1
Blue Screen
Feature
1 0 X X X X X X X 0 = Blue screen OFF.
1 X X X X X X X 1 = Blue screen ON.
08
Saturation Control
6
X X 0 0 0 0 0 0 -40 dB gain (Min. saturation).
X X 1 1 1 1 1 1 +9 dB gain (Max. saturation).
Half Contrast Ena- 1 X 0 X X X X X X 0 = Disabled.
ble
X 1 X X X X X X 1 = Enabled.
Oversize Blanking 1 0 X X X X X X X 0 = Disabled.
Enable
1 X X X X X X X 1 = Enabled.
09
Brightness Control 6
X X 0 0 0 0 0 0 -30% of B/W at Max. contrast.
X X 1 1 1 1 1 1 +30% of B/W at Max. contrast.
RGB Blanking
1 X 0 X X X X X X 0 = Not active (normal operation).
X 1 X X X X X X 1 = Active.
Cut-off Blanking
1 0 X X X X X X X 0 = Enable: RGB output blanked when ICATH voltage
is far from internal cut-off reference (cut-off loop not
locked), during IC start-up.
1 X X X X X X X 1 = Disable: RGB output not blanked by cut-off loop.
49/86