STV224XH/228XH/223XH - ELECTRICAL CHARACTERISTICS
4.9.3 First Loop Filter
Symbol
ILOW
IHIGH
IVLOW
Parameter
Long Time Constant Output Current
Short Time Constant Output Current
Very Long Time Constant
Test Conditions
Min. Typ. Max. Unit
0.10 0.13 0.16 mA
0.30 0.40 0.56 mA
0.03 0.05 0.07 mA
4.9.4 Second Loop Filter
Symbol
CrangeP2
HSHIFT
HDRIFT
Parameter
Control Range from start of horizon-
tal output to flyback pulse
Horizontal Position Control Range
Horizontal Drift with temperature
Test Conditions
Centered horizontal position
From 0°C to 70°C (see Note 9)
Min. Typ. Max. Unit
0 to
12
µs
5 5.25
µs
200 ns
Note 9: This parameter is not tested during production, it is tested during the qualification phase.
4.9.5 Line Flyback Input/Super-Sandcastle Output
Symbol
VBURST
VLINE
VVERT
Twbg
Tdbg
Tvert
VTHLINE
I
Parameter
Test Conditions
Output Voltage during Burst Key
Clamped Input Voltage during Line
Flyback
Output Voltage during Vertical pulse
Burst key Pulse Width
Delay of start of burst key to start of
sync.
Vertical Pulse Width
PLL2 and Line Blanking Threshold
Voltage referred to line level Vline
Vthline/Vline
Input Current
4.9.6 Horizontal Output
Symbol
tW
VLOW
VCCSTART
VCCSTOP
IMax.
VMax.
Tss
Parameter
Test Conditions
Output Pulse Width
Low Output Voltage
VCC Start Level
VCC Stop Level Hysteresis
Maximum allowed Output Current
ISINK = 5mA
VCCSTART - VCCSTOP
Maximum allowed Output Voltage
Output Pulse Duty Cycle in soft-start
mode (tHIGH/(tHIGH+tLOW)
4.9.7 Vertical Output
Symbol
tW
VLOW
fLOCK
fFREE-50
fFREE-60
Parameter
Output Pulse Width
Low Output Voltage
Looking Range
Free Frequency (no Video signal)
Free Frequency (no Video signal)
Test Conditions
Reg 19, d0 = 1
Reg 19, d0 = 0
50-Hz Forced or 50-Hz Auto mode
60-Hz Forced or 60-Hz Auto mode
Min. Typ. Max. Unit
4.8 5.3 5.8 V
2.6 3 3.4 V
1.8 2 2.2 V
3.8
µs
5.2
µs
10.5
lines
83
%
0.1
1 mA
Min. Typ. Max. Unit
26 28 30 µs
0.4 V
5.5 6 6.5 V
0.5 0.6 0.7 V
10 mA
10
V
75
%
Min.
1.5
248
Typ.
10.5
2
0.1
314
264
Max.
2.5
0.5
352
Unit
Lines
V
Lines
Lines
Lines
37/86