Operating features
M25PE80
Table 2. Software protection truth table (sectors 0 to 15, 64-Kbyte granularity)
Sector lock register
Lock
Write
down bit lock bit
Protection status
0
0 Sector unprotected from program/erase/write operations, protection status reversible
0
1 Sector protected from program/erase/write operations, protection status reversible
1
0
Sector unprotected from program/erase/write operations,
Sector protection status cannot be changed except by a reset or power-up.
Sector protected from program/erase/write operations,
1
1
Sector protection status cannot be changed except by a reset or power-up.
Table 3.
Not for new design: TY7 process only, software protection scheme truth
table (sectors 0 and 15)(1) (2) (3)
Sector lock Subsector lock
register
register
Lock Write Lock Write
down lock down lock
bit
bit
bit
bit
Protection status
0
0
Current subsector unprotected from program/erase/write operations,
Current subsector protection status reversible
Current subsector protected from program/erase/write operations,
0
1
Current subsector protection status reversible.
0
1
0
Current subsector unprotected from program/erase/write operations, current
subsector protection status cannot be changed except by a reset or power-up.
0
1
1
Current subsector protected from program/erase/write operations, Current
subsector protection status cannot be changed except by a reset or power-up.
0
1
All subsectors protected from program/erase/write operations, current subsector
protection status reversible
1
1
1
All subsectors protected from program/erase/write operations, current subsector
protection status cannot be changed except by a reset or power-up.
1
0
Current subsector unprotected from program/erase/write operations, all
subsectors protection status cannot be changed except by a reset or power-up
0
1
1
1
Current subsector protected from program/erase/write operations, all subsectors
protection status cannot be changed except by a reset or power-up
1
1
1
All subsectors protected with their protection status cannot be changed except by
a reset or power-up.
1. All other bit combinations are not-applicable.