DC and AC parameters
M25P40
1. Details of how to find the technology process in the marking are given in AN1995, see also Section 12:
Part numbering.
2. 75 MHz operation is available only on the VCC range 2.7 V - 3.6 V; the maximum frequency in the
extended Vcc range 2.3 V to 2.7 V is 40 MHz.
3. Typical values given for TA = 25 °C.
4. tCH + tCL must be greater than or equal to 1/ fC.
5. Value guaranteed by characterization, not 100% tested in production.
6. Expressed as a slew-rate.
7. Only applicable as a constraint for a WRSR instruction when SRWD is set at ‘1’.
Figure 22. Serial input timing
tSHSL
S
tCHSL
tSLCH
tCHSH
tSHCH
C
tDVCH
tCHCL
tCHDX
tCLCH
D
MSB IN
LSB IN
High Impedance
Q
Figure 23. Write Protect setup and hold timing during WRSR when SRWD = 1
W
tWHSL
S
tSHWL
C
D
High Impedance
Q
AI07439