M24M01-R, M24M01-W, M24M01-HR
DC and AC parameters
Table 12. DC characteristics (M24M01-W)
Symbol
Parameter
Test condition (in addition to
those in Table 8)
Min.
Max. Unit
ILI
Input leakage current
(E1, E2, SCL, SDA)
VIN = VSS or VCC
device in Standby mode
±2
µA
ILO Output leakage current
SDA in Hi-Z, external voltage
applied on SDA: VSS or VCC
VCC = 2.5 V, fc= 400 kHz
(rise/fall time < 50 ns)
±2
µA
1
mA
ICC Supply current (Read)
VCC = 5.5 V, fc= 400 kHz
(rise/fall time < 50 ns)
2
mA
ICC0(1) Supply current (Write)
ICC1 Standby supply current
VIL
Input low voltage
(SCL, SDA, WC)
2.5 V < VCC < 5.5 V, fc= 1 MHz
(rise/fall time < 50 ns)
During tW, 2.5 V < VCC < 5.5 V
Device not selected(2),
VIN = VSS or VCC,
VCC = 2.5 V
Device not selected(2),
VIN = VSS or VCC,
VCC = 5.5 V
2.5 V ≤ VCC ≤ 5.5 V
–0.45
2.5
mA
5
mA
5
µA
5
µA
0.3 VCC
VIH
Input high voltage
(SCL, SDA, WC)
2.5 V ≤ VCC ≤ 5.5 V
0.7VCC VCC+1
VOL Output low voltage
IOL = 2.1 mA, VCC = 2.5 V
IOL = 3.0 mA, VCC = 5.5 V
0.4
V
0.4
V
1. Characterized value, not tested in production.
2. The device is not selected after a power-up, a Read instruction (after the Stop condition), or after the
completion of an internal write cycle tW (tW is triggered by the correct decoding of a Write instruction).
Doc ID 12943 Rev 7
23/37