LTC4098/LTC4098-1
ELECTRICAL CHARACTERISTICS The l denotes the specifications which apply over the full operating
temperature range, otherwise specifications are at TA = 25°C. VBUS = 5V, BAT = 3.8V, RCLPROG = 3.01k, unless otherwise noted.
SYMBOL
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
VPROG
VPROG,TRKL
hPROG
VTRKL
ΔVTRKL
VRECHRG
tTERM
tBADBAT
hC/10
VCHRG
ICHRG
RON_CHG
TLIM
NTC
PROG Pin Servo Voltage
PROG Pin Servo Voltage in Trickle
Charge
BAT < VTRKL
Ratio of IBAT to PROG Pin Current
Trickle Charge Threshold Voltage
BAT Rising
Trickle Charge Hystersis Voltage
Recharge Battery Threshold Voltage
Safety Timer Termination Period
Bad Battery Termination Time
End of Charge Indication Current Ratio
CHRG Pin Output Low Voltage
CHRG Pin Input Current
Threshold Voltage Relative to VFLOAT
Timer Starts When BAT = VFLOAT
BAT < VTRKL
(Note 5)
ICHRG = 5mA
BAT = 4.5V, VCHRG = 5V
Battery Charger Power FET
On-Resistance (Between VOUT and BAT)
Junction Temperature in Constant-
Temperature Mode
IBAT = 200mA
1.000
V
0.100
V
1030
mA/mA
2.7
2.85
3
V
130
mV
–80
–100
–120
mV
3.4
4
4.6
Hour
0.43
0.5
0.58
Hour
0.09
0.1
0.11
mA/mA
65
100
mV
0
1
μA
0.18
Ω
110
°C
VCOLD
VHOT
VDIS
INTC
Ideal Diode
Cold Temperature Fault Threshold
Voltage
Hot Temperature Fault Threshold
Voltage
NTC Disable Threshold Voltage
NTC Leakage Current
Rising Threshold
Hysteresis
Falling Threshold
Hysteresis
Falling Threshold
Hysteresis
NTC = 5V
75.0
76.5
78.0 %NTCBIAS
1.5
%NTCBIAS
33.4
34.9
36.4 %NTCBIAS
1.5
%NTCBIAS
0.7
1.7
2.7 %NTCBIAS
50
mV
–50
50
nA
VFWD
Forward Voltage Detection
RDROPOUT
Internal Diode On-Resistance, Dropout
IMAX
Diode Current Limit
Logic (D0, D1, D2)
IVOUT = 10mA
IVOUT = 200mA
15
mV
0.18
Ω
2
A
VIL
Input Low Voltage
VIH
Input High Voltage
IPD
Static Pull-Down Current
VPIN = 1V
0.4
V
1.2
V
2
μA
Note 1: Stresses beyond those listed under Absolute Maximum Ratings
may cause permanent damage to the device. Exposure to any Absolute
Maximum Rating condition for extended periods may affect device
reliability and lifetime.
Note 2: The LTC4098E/LTC4098E-1 are guaranteed to meet performance
specifications from 0°C to 85°C. Specifications over the – 40°C to 85°C
operating temperature range are assured by design, characterization and
correlation with statistical process controls.
Note 3: The LTC4098E/LTC4098E-1 include overtemperature protection
that is intended to protect the device during momentary overload
conditions. Junction temperature will exceed 125°C when overtemperature
protection is active. Continuous operation above the specified maximum
operating junction temperature may impair device reliability.
Note 4: Total input current is the sum of quiescent current, IVBUSQ, and
measured current given by VCLPROG/RCLPROG • (hCLPROG + 1)
Note 5: hC/10 is expressed as a fraction of measured full charge current
with a 5k PROG resistor.
40981fb
4