CS5464
These values may be read and stored for future system AC offset compensation. The value is represented in
two's complement notation in the range of -1.0 Vacoff, Iacoff < 1.0 (-1.0 V2acoff, I2acoff < 1.0), with the binary point
to the right of the MSB.
6.2.5 PulseRateE Register
Address: 15
MSB
LSB
-(20) 2-1
2-2
2-3
2-4
2-5
2-6
2-7
..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Default = 0x800000 = 1.00 (2 kHz @ 4.096 MHz MCLK)
PulseRateE sets the frequency of E1, E2, & E3 pulses. E1, E2, E3 frequency = (MCLK x PulseRateE) / 2048 at
full scale. For a 4 khz sample rate, the maximum pulse rate is 2 khz. The value is represented in two's comple-
ment notation and in the range is -1.0 PulseRateE < 1.0, with the binary point to the right of the MSB. Negative
values have the same effect as positive. See Section 5.5 Energy Pulse Output on page 18 for more information.
6.2.6 Operational Mode (Mode) Register
Address: 16
23
TAMPER
15
-
7
IHPF2
22
-
14
-
6
VHPF
21
-
13
-
5
IHPF
20
-
12
TOFF
4
-
19
-
11
-
3
E3MODE[1]
18
-
10
E2MODE[1]
2
E3MODE[0]
17
-
9
E2MODE[0]
1
POS
16
-
8
VHPF2
0
AFC
Default = 0x000000
TAMPER
Indicates when the meter has been tampered with.
0 = Normal operation. Energy is registered using P. (default)
1 = Tamper condition has been detected. Energy is registered using P2.
TOFF
Tamper Detection Off
0 = Enables tamper detection. (default)
1 = Disables tamper detection.
E2MODE[1:0]
E2 Output Mode
00 = Sign of Active Power (default)
01 = Apparent Power
10 = Tamper Detect
11 = Reserved
VHPF2:IHPF2 High-pass Filter Enable
00 = High-pass filter disabled on voltage channel 2 & current channel 2 (default)
01 = High-pass filter enabled on current channel 2 with all-pass filter on voltage channel 2
10 = High-pass filter enabled on voltage channel 2 with all-pass filter on current channel 2
11 = High-pass filter enabled on voltage channel 2 & current channel 2
VHPF:IHPF
High-pass Filter Enable
00 = High-pass filter disabled on voltage channel 1 & current channel 1 (default)
01 = High-pass filter enabled on current channel 1 with all-pass filter on voltage channel 1
10 = High-pass filter enabled on voltage channel 1 with all-pass filter on current channel 1
11 = High-pass filter enabled on voltage channel 1 & current channel 1