CS5451A
(50 ppm/°C drift) that can be used by connecting
the VREFOUT pin to the VREFIN pin of the de-
vice. If higher accuracy/stability is required, an ex-
ternal reference can be used.
3.8 Power Supply
The low, stable analog power consumption and su-
perior supply rejection of the CS5451A allow for
the use of a simple charge-pump negative supply
generator. The use of a negative supply alleviates
the need for level shifting of the analog inputs. The
CPD pin and capacitor C1 provide the necessary
analog supply current as shown in Figure 5. The
Schottky diodes D1 and D2 are chosen for their low
forward voltages and high-speed capabilities. The
capacitor C2 provides the required charge storage
and bypassing of the negative supply. The CPD
output signal provides the charge pump driver sig-
nal. The frequency of the charge pump driver sig-
nal is synchronous to XIN. The nominal average
frequency is 1 MHz. The level on the VA- pin is
fed back internally so that the CPD output will reg-
ulate the VA- level to -2/3 of VA+ level.
Note the value of C1 in Figure 5. The 40 nF value
is recommended when the input frequency present-
ed to the XIN pin is 4.00 MHz. If the user decides
to use an XIN frequency that is significantly differ-
ent than 4.00 MHz (if the XIN frequency is in-
creased/decreased by more than 5% of 4.00 MHz,
then it is recommended that the user should alter
the value of C1. The percentage change in the value
of C1 (with respect to a reference value of 40 nF)
should be inversely proportional to the percentage
change in the XIN frequency. For example, if the
XIN frequency is increased from 4.00 MHz to
BAT 85
D1
40 nF
C1
D2
BAT 85
CPD
AGND
VA-
C2
1 µF
Figure 5. Generating VA- with a Charge Pump
4.5 MHz, this represents a percentage increase of
12.5%. Therefore, the value of C1 should be re-
duced by 12.5%, making the new value for C1 to be
35 nF. For more information about the operation of
this type of charge pump circuit, the reader can re-
fer to Cirrus Logic, Inc.’s application note AN152:
Using the CS5521/24/28, and CS5525/26 Charge
Pump Drive for External Loads.
3.9 PCB Layout
For optimal performance, the CS5451A should be
placed entirely over an analog ground plane with
both the VA- and DGND pins of the device con-
nected to the analog plane. Place the analog-digital
plane split immediately adjacent to the digital por-
tion of the chip.
Note:
Refer to the CDB5451 Evaluation Board for
suggested layout details and Applications
Note 18 for more detailed layout guidelines.
Before layout, please call for our Free
Schematic Review Service.