datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

CS492305-CL 查看數據表(PDF) - Cirrus Logic

零件编号
产品描述 (功能)
生产厂家
CS492305-CL
Cirrus-Logic
Cirrus Logic 
CS492305-CL Datasheet PDF : 56 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
I2C Start
I2C Stop
SCCLK
SCDIO
AD6 AD5 AD4 AD3 AD2 AD1 AD0 R/W ACK D7 D6 D5 D4 D3 D2 D1 D0 ACK D7 D6 D5 D4 D3 D2 D1 D0 ACK D7 D6 D5 D4 D3 D2 D1 D0 ACK
I2C Write Functional Timing
I2C Start
I2C Stop
SCCLK
SCDIO
AD6 AD5 AD4 AD3 AD2 AD1 AD0 R/W ACK D7 D6 D5 D4 D3 D2 D1 D0 ACK D7 D6 D5 D4 D3 D2 D1 D0 ACK D7 D6 D5 D4 D3 D2 D1 D0 NACK
INTREQ
Note 1
Note 2
I2C Read Functional Timing
Note 3
Note 4
Note 5
Notes: 1. The ACK for the address byte is driven by the CS4923/4/5/6/7/8/9.
2. The ACKs for the data bytes being read from the CS4923/4/5/6/7/8/9 should be driven by the
host.
3. INTREQ is guaranteed to stay low until the rising edge of SCCLK for last bit of the last byte to
be transferred out of the CS4923/4/5/6/7/8/9
4. A NOACK should be sent by the host after the last byte read to indicate the end of the read
cycle.
5. INTREQ is guaranteed to stay high until the next rising edge of SCCLK (for the ACK/NACK
bit) at which point it may go low again if there is new data to be read. The condition of INTREQ
going low at this point should be treated as a new read condition and a new start condition
followed by an address byte should be sent.
Figure 20. I2C Timing