datasheetbank_Logo
数据手册搜索引擎和 Datasheet免费下载 PDF

CS4384 查看數據表(PDF) - Cirrus Logic

零件编号
产品描述 (功能)
生产厂家
CS4384 Datasheet PDF : 50 Pages
First Prev 31 32 33 34 35 36 37 38 39 40 Next Last
CS4384
Addr Function
7
14h Vol. Control A4 A4_VOL7
default
0
15h Vol. Control B4 B4_VOL7
default
0
16h PCM clock mode Reserved
default
0
6
A4_VOL6
0
B4_VOL6
0
Reserved
0
5
A4_VOL5
0
B4_VOL5
0
MCLKDIV
0
4
A4_VOL4
0
B4_VOL4
0
Reserved
0
3
A4_VOL3
0
B4_VOL3
0
Reserved
0
2
A4_VOL2
0
B4_VOL2
0
Reserved
0
1
A4_VOL1
0
B4_VOL1
0
Reserved
0
0
A4_VOL0
0
B4_VOL0
0
Reserved
0
5. REGISTER DESCRIPTION
Note: All registers are read/write in I²C mode and write only in SPI, unless otherwise noted.
5.1 Chip Revision (address 01h)
7
PART4
0
6
PART3
0
5
PART2
0
4
PART1
0
3
PART0
0
2
REV2
-
1
REV1
-
0
REV0
-
5.1.1
Part Number ID (part) [Read Only]
00000- CS4384
Revision ID (REV) [Read Only]
000 - Revision A0
001 - Revision B0
Function:
This read-only register can be used to identify the model and revision number of the device.
5.2 Mode Control 1 (address 02h)
7
CPEN
0
6
FREEZE
0
5
DSD/PCM
0
4
DAC4_DIS
0
3
DAC3_DIS
0
2
DAC2_DIS
0
1
DAC1_DIS
0
0
PDN
1
5.2.1
Control Port Enable (CPEN)
Default = 0
0 - Disabled
1 - Enabled
Function:
This bit defaults to 0, allowing the device to power-up in Stand-Alone mode. The Control port mode can
be accessed by setting this bit to 1. This will allow the operation of the device to be controlled by the reg-
isters and the pin definitions will conform to Control Port Mode. To accomplish a clean power-up, the user
should write this bit within 10 ms following the release of Reset.
34
DS620A1

Share Link: 