4. PIN DESCRIPTION
48 47 46 45 44 43 42 41 40 39 38 37
DSDA2
DSDB1
DSDA1
VD
GND
MCLK
LRCK1(DSD_EN)
SDIN1
SCLK1
LRCK2
SDIN2
SCLK2
1
36
2
35
3
34
4
33
5
32
6
CS4362
31
7
30
8
29
9
28
10
27
11
26
12
25
13 14 15 16 17 1 8 19 20 21 22 23 24
AOUTA2-
AOUTA2+
AOUTB2+
AOUTB2-
VA
GND
AOUTA3-
AOUTA3+
AOUTB3+
AOUTB3-
MUTEC2
MUTEC3
CS4362
Pin Name
VD
GND
MCLK
LRCK1
LRCK2
SDIN1
SDIN2
SDIN3
SCLK1
SCLK2
TST
RST
VA
VLS
VLC
# Pin Description
4 Digital Power (Input) - Positive power supply for the digital section. Refer to the Recom-
mended Operating Conditions for appropriate voltages.
5 Ground (Input) - Ground reference. Should be connected to analog ground.
31
6 Master Clock (Input) - Clock source for the delta-sigma modulator and digital filters. Table 5
illustrates several standard audio sample rates and the required master clock frequencies.
7 Left Right Clock (Input) - Determines which channel, Left or Right, is currently active on the
10 serial audio data line. The frequency of the left/right clock must be at the audio sample rate, Fs.
8 Serial Data Input (Input) - Input for twos complement serial audio data.
11
13
9 Serial Clock (Input) - Serial clocks for the serial audio interface.
12
14 Test - These pins need to be tied to analog ground.
44
45
19 Reset (Input) - The device enters a low power mode and all internal registers are reset to their
default settings when low.
32 Analog Power (Input) - Positive power supply for the analog section. Refer to the Recom-
mended Operating Conditions for appropriate voltages.
43 Serial Audio Interface Power (Input) - Determines the required signal level for the serial audio
interface. Refer to the Recommended Operating Conditions for appropriate voltages.
18 Control Port Power (Input) - Determines the required signal level for the control port and stand
alone configuration pins. Refer to the Recommended Operating Conditions for appropriate volt-
ages.