C8051F91x-C8051F90x
4. Electrical Characteristics
Throughout the Electrical Characteristics chapter, “VDD” refers to the VDD/DC+ Supply Voltage.
Blue indicates a feature only available on ‘F912 and ‘F902 devices.
4.1. Absolute Maximum Specifications
Table 4.1. Absolute Maximum Ratings
Parameter
Conditions
Min
Ambient temperature under bias
–55
Storage Temperature
–65
Voltage on any Port I/O Pin or VDD > 2.2 V
–0.3
RST with respect to GND
VDD < 2.2 V
–0.3
Voltage on VBAT with respect to One-Cell Mode (F912/02
–0.3
GND
One-Cell Mode (F911/01) –0.3
Two-Cell Mode
–0.3
Voltage on VDD/DC+ with respect
–0.3
to GND
Maximum total current through
—
VBAT, DCEN, VDD/DC+ or GND
Maximum current through RST or
—
any Port pin
Maximum total current through all
—
Port pins
DC-DC Converter Output Power
—
Typ
Max
Units
—
125
°C
—
150
°C
—
5.8
V
— VDD + 3.6
—
4.0
V
—
2.0
—
4.0
—
4.0
V
—
500
mA
—
100
mA
—
200
mA
—
110
mW
Note: Stresses above those listed under “Absolute Maximum Ratings” may cause permanent damage to the device.
This is a stress rating only and functional operation of the devices at those or any other conditions above those
indicated in the operation listings of this specification is not implied. Exposure to maximum rating conditions for
extended periods may affect device reliability.
36