R8C/26 Group, R8C/27 Group
5. Electrical Characteristics
Suspend request
(maskable interrupt request)
FMR46
Figure 5.21 Time delay until Suspend
Fixed time
Clock-dependent
time
td(SR-SUS)
Access restart
Table 5.39 Voltage Detection 1 Circuit Electrical Characteristics
Symbol
Vdet1
td(Vdet1-A)
−
td(E-A)
Vccmin
Parameter
Voltage detection level(2, 4)
Voltage monitor 1 reset generation time(5)
Voltage detection circuit self power consumption
Waiting time until voltage detection circuit operation
starts(3)
MCU operating voltage minimum value
Condition
Standard
Unit
Min. Typ. Max.
2.70 2.85 3.0
V
−
40 200 µs
VCA26 = 1, VCC = 5.0 V −
0.6
−
µA
−
−
100 µs
2.70
−
−
V
NOTES:
1. The measurement condition is VCC = 2.7 to 5.5 V and Topr = -40 to 85°C (J version) / -40 to 125°C (K version).
2. Hold Vdet2 > Vdet1.
3. Necessary time until the voltage detection circuit operates when setting to 1 again after setting the VCA26 bit in the VCA2
register to 0.
4. This parameter shows the voltage detection level when the power supply drops.
The voltage detection level when the power supply rises is higher than the voltage detection level when the power supply
drops by approximately 0.1 V.
5. Time until the voltage monitor 1 reset is generated after the voltage passes Vdet1 when VCC falls. When using the digital filter,
its sampling time is added to td(Vdet1-A). When using the voltage monitor 1 reset, maintain this time until VCC = 2.0 V after the
voltage passes Vdet1 when the power supply falls.
Table 5.40 Voltage Detection 2 Circuit Electrical Characteristics
Symbol
Vdet2
td(Vdet2-A)
−
td(E-A)
Parameter
Voltage detection level(2)
Voltage monitor 2 reset/interrupt request generation
time(3, 5)
Voltage detection circuit self power consumption
Waiting time until voltage detection circuit operation
starts(4)
Condition
Standard
Unit
Min. Typ. Max.
3.3 3.6 3.9
V
−
40 200 µs
VCA27 = 1, VCC = 5.0 V −
−
0.6
−
µA
−
100 µs
NOTES:
1. The measurement condition is VCC = 2.7 to 5.5 V and Topr = -40 to 85°C (J version) / -40 to 125°C (K version).
2. Hold Vdet2 > Vdet1.
3. Time until the voltage monitor 2 reset/interrupt request is generated after the voltage passes Vdet2.
4. Necessary time until the voltage detection circuit operates after setting to 1 again after setting the VCA27 bit in the VCA2
register to 0.
5. When using the digital filter, its sampling time is added to td(Vdet2-A). When using the voltage monitor 2 reset, maintain this time
until VCC = 2.0 V after the voltage passes Vdet2 when the power supply falls.
Rev.2.10 Sep 26, 2008 Page 53 of 69
REJ03B0168-0210