CS61318
2.11.1 Control Register 1: Address 0x10
7 (MSB)
TAOS
6
LLOOP
5
RLOOP
4
Reserved
Set to “0”
3
Reserved
Set to “0”
2
HDB3
1
NLOOP
0 (LSB)
LOS
TAOS
LLOOP
RLOOP
BITS 4:3
HDB3
NLOOP
LOS
Transmit All Ones Select
When TAOS = 1, all ones are transmitted at the TCLK frequency
Local Loopback
When LLOOP = 1, data input at TPOS, TNEG (TDATA) is internally looped back and output on
RPOS, RNEG (RDATA). TCLK is routed to RCLK, through the jitter attenuator, if activated.
Remote Loopback
When RLOOP = 1, clock and data recovered by the receiver are sent back through the transmit
path and retransmitted. The clock and data are routed through the jitter attenuator, if activated.
Reserved - Set Bits 3 & 4 to “0” for proper operation.
Setting HDB3 to “1” enables HDB3 encoding and decoding.
Network Loopback
NLOOP = 1 when a network loopback code has been detected on the received signal.
An interrupt will occur when NLOOP changes state unless a “1” is written to NLOOP disabling
the interrupt.
Loss Of Signal
LOS = 1 when the loss of signal criteria have been met (See Receiver Loss of Signal).
LOS = 0 when a valid signal is being received.
Writing a “1” to LOS disables interrupts due to LOS and the LOS Change indication in bits 5
and 6.