ST52T410/ST52T420/E420
11.3 Recommended Operating Condition
Operating condition: VDD=5V±10%; TA= -25/85°C (unless otherwise specified).
Table 11.4 Recommended Operating Conditions
Symbol
VDD
VPP
VO
VDDA,VSSA
Parameter
Operating Supply1)2)
Programming Voltage
Output Voltage
Analog Supply Voltage1)
Test Condition
Refer to Figure 11.3
VSS≤VSSA≤VDDA≤VDD
Min.
4.75
11.4
VSS
VSS
Typ.
5.0
12
Max
5.25
12.6
VDD
VDD
Unit
V
fOSC 1)2)
Oscillator Frequency
1
20
MHz
Notes:
1. The maximum difference between VSS and VSSA, and between VDD and VDDA, must be less than 0.6 V
in module. The minimum value of VDDA is 3 V.
2. VDD depend on fOSC , see Figure 11.3
3. The fOSC min allowed to use the A/D Converter is 2 MHz
4. Lower VDD decreasing fosc (see Figure 11.3). Data illustrated in the figure are characterized but not test-
ed.
Figure 11.3 fosc Maximum Operating Frequency versus VDD supply
20
18
16
14
12
10
8
6
4
2
0
0
Functionality not guarateed in this area
Functionality guarateed in this area
Functionality not guarateed in this area
0.5
1
1.5
2
2.5
3
3.5
4
4.5
5
5.5
Vdd (V)
68/84