datasheetbank_Logo
전자부품 반도체 검색엔진( 무료 PDF 다운로드 ) - 데이터시트뱅크

CS4360(2004) 데이터 시트보기 (PDF) - Cirrus Logic

부품명
상세내역
제조사
CS4360
(Rev.:2004)
Cirrus-Logic
Cirrus Logic 
CS4360 Datasheet PDF : 37 Pages
First Prev 31 32 33 34 35 36 37
CS4360
6.4 VOLUME CONTROL (ADDRESSES 06H - 0BH)
7
xx_MUTE
0
6
xx_VOL6
0
5
xx_VOL5
0
4
xx_VOL4
0
3
xx_VOL3
0
2
xx_VOL2
0
1
xx_VOL1
0
0
xx_VOL0
0
6.4.1
MUTE (MUTE) BIT 7
Default = 0
0 - Disabled
1 - Enabled
Function:
The Digital-to-Analog converter output will mute when enabled. The quiescent voltage on the output
will be retained. The muting function is affected, similar to attenuation changes, by the Soft and Zero
Cross bits. The MUTEC pin will become active during the mute period if the Mute function is enabled
for both channels in the pair.
6.4.2 VOLUME CONTROL (XX_VOL) BIT 0-6
Default = 0
Function:
The Digital Volume Control registers allow independent control of the signal levels in 1-dB increments
from 0 to -119 dB. Volume settings are decoded as shown in Table 10. The volume changes are im-
plemented as dictated by the Soft Ramp and Zero Cross bits. All volume settings less than -119 dB
are equivalent to enabling the MUTE bit.
Binary Code
0001010
0010100
0101000
0111100
1011010
Decimal Value
10
20
40
60
90
Volume Setting
-10 dB
-20 dB
-40 dB
-60 dB
-90 dB
Table 10. Example Digital Volume Settings
6.5 MODE CONTROL 2 (ADDRESS 0DH)
7
SZC1
1
6
SZC0
0
5
CPEN
0
4
PDN
1
3
POPG
1
2
FREEZE
0
1
MCLKDIV
0
0
SNGLVOL
0
6.5.1
SOFT RAMP AND ZERO CROSS CONTROL (SZC) BIT 6-7
Default = 10
00 - Immediate Change
01 - Zero Cross
10 - Soft Ramp
11 - Soft Ramp and Zero Cross
Function:
Immediate Change
When Immediate Change is selected all level changes will be implemented immediately in one step.
DS517F2
33

Share Link: 