MC74AC11 MC74ACT11
RECOMMENDED OPERATING CONDITIONS
Symbol
Parameter
Min
Typ
VCC
Supply Voltage
′AC
′ACT
2.0
5.0
4.5
5.0
Vin, Vout
DC Input Voltage, Output Voltage (Ref. to GND)
0
Input Rise and Fall Time (Note 1)
tr, tf
′AC Devices except Schmitt Inputs
VCC @ 3.0 V
150
VCC @ 4.5 V
40
VCC @ 5.5 V
25
Input Rise and Fall Time (Note 2)
VCC @ 4.5 V
10
tr, tf
′ACT Devices except Schmitt Inputs
VCC @ 5.5 V
8.0
TJ
Junction Temperature (PDIP)
TA
Operating Ambient Temperature Range
–40
25
IOH
Output Current — High
IOL
Output Current — Low
1. Vin from 30% to 70% VCC; see individual Data Sheets for devices that differ from the typical input rise and fall times.
2. Vin from 0.8 V to 2.0 V; see individual Data Sheets for devices that differ from the typical input rise and fall times.
DC CHARACTERISTICS
74AC
74AC
Symbol
Parameter
VCC
(V)
TA = +25°C
TA =
–40°C to +85°C
Unit
Typ Guaranteed Limits
VIH
Minimum High Level
Input Voltage
3.0
1.5 2.1
2.1
4.5 2.25 3.15
3.15
V
5.5 2.75 3.85
3.85
VIL
Maximum Low Level
Input Voltage
3.0
1.5 0.9
0.9
4.5 2.25 1.35
1.35
V
5.5 2.75 1.65
1.65
VOH
Minimum High Level
Output Voltage
3.0 2.99 2.9
2.9
4.5 4.49 4.4
4.4
V
5.5 5.49 5.4
5.4
VOL
Maximum Low Level
Output Voltage
3.0
2.56
2.46
V
4.5
3.86
3.76
5.5
4.86
4.76
3.0 0.002 0.1
0.1
4.5 0.001 0.1
0.1
V
5.5 0.001 0.1
0.1
IIN
Maximum Input
Leakage Current
3.0
0.36
0.44
V
4.5
0.36
0.44
5.5
0.36
0.44
5.5
±0.1
±1.0
µA
IOLD
IOHD
ICC
†Minimum Dynamic
Output Current
Maximum Quiescent
Supply Current
5.5
75
mA
5.5
–75
mA
5.5
4.0
40
µA
* All outputs loaded; thresholds on input associated with output under test.
† Maximum test duration 2.0 ms, one output loaded at a time.
Note: IIN and ICC @ 3.0 V are guaranteed to be less than or equal to the respective limit @ 5.5 V VCC.
Max
6.0
5.5
VCC
Unit
V
V
ns/V
ns/V
140
°C
85
°C
–24
mA
24
mA
Conditions
VOUT = 0.1 V
or VCC – 0.1 V
VOUT = 0.1 V
or VCC – 0.1 V
IOUT = –50 µA
*VIN = VIL or VIH
–12 mA
IOH
–24 mA
–24 mA
IOUT = 50 µA
*VIN = VIL or VIH
12 mA
IOL
24 mA
24 mA
VI = VCC, GND
VOLD = 1.65 V Max
VOHD = 3.85 V Min
VIN = VCC or GND
FACT DATA
5-2