DC Electrical Characteristics for ACT
Symbol
Parameter
VIH
Minimum HIGH Level
Input Voltage
VIL
Maximum LOW Level
Input Voltage
VOH
Minimum HIGH Level
Output Voltage
VCC
TA = +25°C
TA = −40°C to +85°C
(V)
Typ
Guaranteed Limits
4.5
1.5
2.0
2.0
5.5
1.5
2.0
2.0
4.5
1.5
0.8
0.8
5.5
1.5
0.8
0.8
4.5
4.49
4.4
4.4
5.5
5.49
5.4
5.4
VOL
Maximum LOW Level
Output Voltage
4.5
3.86
3.76
5.5
4.86
4.76
4.5
0.001
0.1
0.1
5.5
0.001
0.1
0.1
4.5
0.36
5.5
0.36
IIN
Maximum Input
Leakage Current
5.5
±0.1
IOZ
Maximum 3-STATE
5.5
±0.5
Current
ICCT
IOLD
IOHD
ICC
Maximum ICC/Input
Minimum Dynamic
Output Current (Note 6)
Maximum Quiescent
Supply Current
5.5
0.6
5.5
5.5
5.5
4.0
Note 5: All outputs loaded; thresholds on input associated with output under test.
Note 6: Maximum test duration 2.0 ms, one output loaded at a time.
Note 7: May be measured per the JEDEC Alternate Method.
0.44
0.44
±1.0
±5.0
1.5
75
−75
40.0
Units
V
V
V
V
V
V
µA
µA
mA
mA
mA
µA
Conditions
VOUT = 0.1V
or VCC − 0.1V
VOUT = 0.1V
or VCC − 0.1V
IOUT = −50 µA
VIN = VIL or VIH
IOH = −24 mA
IOH = −24 mA (Note 5)
IOUT = 50 µA
VIN = VIL or VIH
IOL = 24 mA
IOL = 24 mA (Note 5)
VI = VCC, GND
VI = VIL, VIH
VO = VCC, GND
VI = VCC − 2.1V (Note 7)
VOLD = 1.65V Max
VOHD = 3.85V Min
VIN = VCC
or GND
3
www.fairchildsemi.com