datasheetbank_Logo
データシート検索エンジンとフリーデータシート

TDA7563ASM_08 データシートの表示(PDF) - STMicroelectronics

部品番号
コンポーネント説明
メーカー
TDA7563ASM_08 Datasheet PDF : 35 Pages
First Prev 11 12 13 14 15 16 17 18 19 20 Next Last
TDA7563A
Diagnostics functional description
Concerning SHORT ACROSS THE SPEAKER / OPEN SPEAKER, the threshold varies
from 26 dB to 12 dB gain setting, since different loads are expected (either normal speaker's
impedance or high impedance). The values in case of 26 dB gain are as follows:
Figure 23. Thresholds for short across the speaker/open speaker
S.C. across Load x Normal Operation x
Open Load
0V
0.5Ω 1.5Ω
70Ω
130Ω
Infinite
D01AU1254
If the Line-Driver mode (Gv= 12 dB and Line Driver Mode diagnostic = 1) is selected, the
same thresholds will change as follows:
Figure 24. Thresholds for line-drivers
S.C. across Load x Normal Operation x
Open Load
0Ω
1.5Ω 4.5Ω
200Ω 400Ω
infinite
D01AU1252
3.2
Permanent diagnostics
Detectable conventional faults are:
– Short to GND
– Short to Vs
– Short across the speaker
The following additional features are provided:
– Output offset detection
The TDA7563A has 2 operating statuses:
1. RESTART mode. The diagnostic is not enabled. Each audio channel operates
independently from each other. If any of the a.m. faults occurs, only the channel(s)
interested is shut down. A check of the output status is made every 1 ms (Figure 25).
Restart takes place when the overload is removed.
2. DIAGNOSTIC mode. It is enabled via I2C bus and self activates if an output overload
(such to cause the intervention of the short-circuit protection) occurs to the speakers
outputs. Once activated, the diagnostics procedure develops as follows (Figure 26):
– To avoid momentary re-circulation spikes from giving erroneous diagnostics, a
check of the output status is made after 1ms: if normal situation (no overloads) is
detected, the diagnostic is not performed and the channel returns back active.
– Instead, if an overload is detected during the check after 1 ms, then a diagnostic
cycle having a duration of about 100 ms is started.
– After a diagnostic cycle, the audio channel interested by the fault is switched to
RESTART mode. The relevant data are stored inside the device and can be read
by the microprocessor. When one cycle has terminated, the next one is activated
15/35

Share Link: 

datasheetbank.com [ Privacy Policy ] [ Request Datasheet ] [ Contact Us ]