CS5490
6.6.21 System Gain (SysGAIN) – Page 16, Address 60
MSB
LSB
-(21) 20
2-1
2-2
2-3
2-4
2-5
2-6
..... 2-16 2-17 2-18 2-19 2-20 2-21 2-22
Default = 0x50 0000 (1.25)
System Gain (SysGAIN) is applied to all channels.
By default, SysGAIN = 1.25, but can be finely adjusted to compensate for voltage reference error. It is a two's
complement value in the range of -2.0 value 2.0, with the binary point to the right of the second MSB. Val-
ues should be kept within 5% of 1.25.
6.6.22 Rogowski Coil Integrator Gain (IntGAIN) – Page 18, Address 43
MSB
LSB
-(20) 2-1
2-2
2-3
2-4
2-5
2-6
2-7
..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Default = 0x14 3958
Gain for the Rogowski coil integrator. This must be programmed accordingly for 50Hz and 60Hz (0.158 for
50Hz, 0.1875 for 60Hz).
This is a two’s complement value in the range of -1.0 value 1.0, with the binary point to the right of the
MSB. Negative values are not used.
6.6.23 System Time (Time) – Page 16, Address 61
MSB
LSB
223
222
221
220
219
218
217
216
.....
26
25
24
23
22
21
20
Default = 0x00 0000
System Time (Time) is measured in output word rate (OWR) samples.
This is an unsigned integer in the range of 0 to 16,777,215 samples. At OWR = 4.0 kHz, OWR will overflow
every 1 hour, 9 minutes, 54 seconds. Time can be used by the application to manage real-time events.
6.6.24 Voltage Sag Duration (VSagDUR) – Page 17, Address 0
MSB
LSB
0
222
221
220
219
218
217
216
.....
26
25
24
23
22
21
20
Default = 0x00 0000
Voltage sag duration, VSagDUR, determines the count of output word rate (OWR) samples utilized to deter-
mine a sag event.
These are integers in the range of 0 to 8,388,607 samples. A value of zero disables the feature.
42