9. BASIC APPLICATION CIRCUITS
Figure 19 shows the CS5464 configured to measure
power in a single-phase, 2-wire system while operating
in a single-supply configuration. In this diagram, a shunt
resistor is used to sense the line current and a voltage
divider is used to sense the line voltage. In this type of
shunt-resistor configuration, the common-mode level of
the CS5464 must be referenced to the line side of the
power line. This means that the common-mode poten-
tial of the CS5464 will track the high-voltage levels, as
well as low-voltage levels, with respect to earth ground.
Isolation circuitry is required when an earth-ground-ref-
erenced communication interface is connected. A cur-
rent transformer, or CT, is connected to the return line
current, which implements the tamper detection circuit.
5 k
10 k
L2
LINE
L1
VOLTAGE
500
500
10
470 nF
470 µF
0.1 µF
18
VA+
0.1 µF
3
VD+
R2
R1
CT
LOAD
CS5464
21
CV-
9 VIN+
CVdiff
PFMON
CPUCLK 2
XOUT 1
R V-
CV+
10 VIN-
XIN 28
R I-
RShunt
19 IIN-
C I-
C Idiff
R
I+
1k
RBurden
1k
Note:
C I+
RI-
20 IIN+
15
IIN2-
C Idiff
16 IIN2+
RI+
0.1 µF
12 VREFIN
11 VREFOUT
AGND
Indicates common (floating) return.
17
23
RESET
CS 7
SDI 27
SDO 6
SCLK 5
INT 24
E2 26
E1 25
13
TEST1
TEST2 14
DGND
4
4.096 MHz
Optional
Clock
Source
Serial
Data
Interface
Pulse Output
Counter
Figure 19. Typical Connection Diagram (Single-phase, 2-wire Direct Connect to Power Line)