PHOTOTRANSISTOR OPTICAL
INTERRUPTER SWITCH
QVE00034
Fig. 5 Collector Current vs. Temperature
5
4.5 Normalized to
IF = 100 mA
IF = 20 mA, VCE = 5 V, TA = 25˚C
4
3.5
IF = 60 mA
3
2.5
2
IF = 30 mA
1.5
IF = 20 mA
1
IF = 10 mA
0.5
IF = 5 mA
0
-55
-40
-20
0
20
40
60
80
100
Temp(C)
Fig. 6 Collector Current vs. Forward Current
3
2.5
2
1.5
TA = 25˚C
VCE = 10 V
1
Normalized to
IF = 20 mA
0.5
0
0
5
10 15 20 25
30 35 40 45 50 55
IF (mA)
1.1
1.05
1
0.95
0.9
0.85
0.8
0.75
0.7
0.65
0.6
0.55
0.5
1
Fig. 7 Rise Time vs. Load Resistance
T(on)
TA = 25˚C
PW = 300 µs
PRR = 100 µs
VCC = 5 V
Normalized
to RL = 2k Ω
2
3
4
5
6
7
8
9
10
RL(kΩ)
4.5
4.25
4
3.75
3.5
3.25
3
2.75
2.5
2.25
2
1.75
1.5
1.25
1
0.75
0.5
0.25
0
1
Fig. 8 Fall Time vs. Load Resistance
T(off)
TA = 25˚C
PW = 300 µs
PRR = 100 µs
VCC = 5 V
Normalized
to RL = 2k Ω
2
3
4
5
6
7
8
9
10
RL(kΩ)
Fig. 9 Forward Voltage vs. Forward Current
55
50
45
40
35
30
25
20
15
10
5
0
0
TA = 30˚C
TA = 25˚C
TA = 70˚C
0.2
0.4
0.6
0.8
1
VF(V)
1.2
1.4
1.6
1.8
© 2003 Fairchild Semiconductor Corporation
Page 4 of 5
4/14/03