Signal
Signal Relays
R10 Series Relay (Continued)
Potter & Brumfield
Coil versions, DC coil (continued)
Coil
Maximum
Operate
Coil
code coil current
current
resistance
mADC
mADC
Ω±10%
J - sensitive DC current adjustment – R10S types only
2 pole
J5001)
–
6.3
500
J1.0K
–
4.5
1000
J2.5K2)
–
2.9
2500
J5.0K
–
2
5000
J10.0K3)
–
1.4
10000
J16.0K
–
1.2
16000
J30.0K
–
0.8
30000
4 pole
J500
–
9
500
J1.0K
–
6.5
1000
J2.5K2)
–
4.1
2500
J5.0K3)
–
2.9
5000
J10.0K
–
2
10000
J16.0K
–
1.4
16000
J30.0K
–
1.2
30000
1) Suggested for 5VDC operation
2) Suggested for 12VDC operation
3) Suggested for 24VDC operation
Pick-up
coil power
mW
20
20
25
20
20
25
20
45
45
45
45
40
35
45
JJ - ultrasensitive DC current adjustment
1 pole
JJ1.0K
45
4.5
1000
20
JJ2.5K
28
2.9
2500
25
JJ5.0K
20
2.1
5000
25
JJ10.0K 14
1.5
10000
25
JJ15.0K 11.5
1.2
15000
25
JJ30.0K 8.3
0.85
30000
25
2 pole
JJ1.0K
45
6.5
1000
45
JJ2.5K
28
4.1
2500
45
JJ5.0K
20
2.9
5000
45
JJ10.0K 14
2
10000
40
JJ15.0K 11.5
1.7
15000
45
JJ30.0K 8.3
1.2
30000
45
4 pole
JJ1.0K
45
9
1000
85
JJ2.5K
28
5.8
2500
85
JJ5.0K
20
4.1
5000
85
JJ10.0K 14
3
10000
90
JJ15.0K 11.5
2.4
15000
85
JJ30.0K 8.3
1.7
30000
90
All figures are given for coil without preenergization, at ambient temperature +23°C.
Coil versions, AC coil (dual coil diode rectified construction)
Coil
Rated
Operate
Coil
code
voltage
voltage
resistance
VAC
VAC
Ω±20%
Standard AC
2 and 4 pole
6V
6
5
25
12V
12
9
120
24V
24
18
500
48V
48
36
2000
115V
115
86
9000
6 and 8 pole
6V
6
5
15
12V
12
9
90
24V
24
18
350
48V
48
36
1400
115V
115
86
7500
All figures are given for coil without preenergization, at ambient temperature +23°C.
Operative Range
R10 Relays (DC Only) Typical Ranges of Operations @ 25°C
(Curves for reference only. If specific
values are required, testing is required.)
30
12
25
Typical Operate
10
and Release Time
(all contact configurations)
20
8
15
6
Release Time
(no suppression)
10
4
5
2
Operate Time
1.0 1.33 1.5
2.0
2.5
3.0
Multiple of Max. Pull-in Voltage or Current
R10 Ultra-Sensitive “SS” and “JJ” Typical Ranges of Operation @ 25°C
(Curves for reference only. If specific
values are required, testing is required.)
50
10
Typical Operate
40
and Release Time
8
(all contact configurations)
30
6
Release Time
20
(no suppression) 4
10
Operate Time 2
1.0 1.5 2.0
3.0
4.0
Multiple of Max. Pull-in Voltage or Current
Typical Coil Inductance
500
100
50
10
1.0
0.5
0.1
10
Armature (open)
Armature (closed)
50 100
500 1K
5K 10K
Coil Resistance (Ohms)
100K
08-2015, Rev. 0815
www.te.com
© 2015 Tyco Electronics Corporation,
a TE Connectivity Ltd. company
Datasheets and product specification
according to IEC 61810-1 and to be used
only together with the ‘Definitions’ section.
3
Datasheets and product data is subject to the Datasheets, product data, ‘Definitions’ sec-
terms of the disclaimer and all chapters of
tion, application notes and all specifications
the ‘Definitions’ section, available at
are subject to change.
http://relays.te.com/definitions