CS5490
6.6.54 Temperature Offset (TOFF) – Page 16, Address 55
MSB
LSB
-(27) 26
25
24
23
22
21
20
..... 2-10 2-11 2-12 2-13 2-14 2-15 2-16
Default = 0xD5 3998
Register TOFF is used to offset the Temperature register (T), and is a two's complement value in the range of
-128.0value128.0 (°C), with the binary point to the right of bit 16.
Register T can be rescaled by the application using the TGAIN and TOFF registers. Refer to section 7.3 Tem-
perature Sensor Calibration on page 53 for more information.
6.6.55 Calibration Scale (Scale) – Page18, Address 63
MSB
LSB
-(20) 2-1
2-2
2-3
2-4
2-5
2-6
2-7
..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Default = 0x4C CCCC (0.6)
The Scale register is used in the gain calibration to set the level of calibrated results of I-channel RMS. During
gain calibration, the IRMS results register is divided into the Scale register. The quotient is put into the IGAIN
register. It is a two's complement value in the range of -1.0 value 1.0, with the binary point to the right of
the MSB. Negative values are not used.
6.6.56 Zero-crossing Number (ZXNUM) – Page 0, Address 55
MSB
LSB
223
222
221
220
219
218
217
216
.....
26
25
24
23
22
21
20
Default = 0x00 0064 (100)
ZXNUM is the number of zero crossings used for line frequency measurement. It is an integer in the range of
1 to 8,388,607. Zero should not be used.
6.6.57 V-channel Zero-crossing Threshold (VZXLEVEL) – Page 18, Address 58
MSB
LSB
-(20) 2-1
2-2
2-3
2-4
2-5
2-6
2-7
..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Default = 0x10 0000 (0.125)
VZXLEVEL is the level that the peak instantaneous voltage must exceed for the zero-crossing detection to
function. This is a two's complement value in the range of -1.0 value<1.0, with the binary point to the right of
the MSB. Negative values are not used.
6.6.58 I-channel Zero-crossing Threshold (IZXLEVEL) – Page 18, Address 24
MSB
LSB
-(20) 2-1
2-2
2-3
2-4
2-5
2-6
2-7
..... 2-17 2-18 2-19 2-20 2-21 2-22 2-23
Default = 0x10 0000 (0.125)
IZXLEVEL is the level that the peak instantaneous current must exceed for the zero-crossing detection to func-
tion. This is a two's complement value in the range of -1.0value<1.0, with the binary point to the right of the
MSB. Negative values are not used.
50