VB027SP-E
Electrical specifications
2.3
Electrical characteristics
VCC = 13.5 V; Vd = 5 V; Tj = 25 °C; Rcoil = 510 mΩ; Lcoil = 7 mH unless otherwise specified.
Table 5. Electrical characteristics
Symbol
Parameter
Test conditions
Min Typ Max Unit
Vcl
High voltage clamp
Vcg(sat)
Vcg(sat)td
Power stage saturation voltage
Power stage saturation voltage
derating in temperature
Id(off) Power-off supply current
Id(on) Power-on supply current
Vd
Icl
Icl(td)
Driving stage supply voltage
Collector current limit
Collector current limit drift with
temperature
VIN = 0.4 V; -40 °C Tj 125 °C;
IC = 6 A
IC = 6 A; VIN = 4 V; Id = 80 mA
IC = 6 A; VIN = 4 V;
-40 °C Tj 125 °C; Id = 85 mA
VIN = 0.4 V
VIN = 4 V; IC = 6 A;
-40 °C Tj 125 °C
VIN = 4 V(1)
See Figure 3
VINH
VINL
IINH
VdiagH
VdiagL
IC(diag1)
IC(diag1)td
High level input voltage
HVC < 2 V
Low level input voltage
IC < 2 mA; HVC = VCC
High level input current
VIN = 4 V
High level diagnostic output voltage REXT = 22 KΩ (See Figure 6)
Low level diagnostic output voltage REXT = 22 KΩ (See Figure 6)
First threshold level collector current
First threshold level collector current
drift with temperature
See Figure 4
300 360 400 V
1.5
V
2
V
8 mA
130 mA
4.5
5.5 V
8 8.5 9
A
4
5.5 V
0
0.8 V
40
200 µA
3.5
(2)
Vd
V
0.5 V
4.25 4.5 4.75 A
IC(diag2)
Second threshold level collector
current
5.45 5.8 6.15 A
IC(diag2)td
Second threshold level collector
current drift with temperature
See Figure 5
td(off)
tf(off)
td(diag)
tr(diag)
Turn-off delay time of output current IC = 5.5 A
Turn-off fall time of output current IC = 5.5 A
Delay time of diagnostic current
REXT = 22 KΩ (See Figure 6)
Turn-on rise time of diagnostic
current
REXT = 22 KΩ (See Figure 6)
tf(diag)
Turn-off fall time of diagnostic
current
REXT = 22 KΩ (See Figure 6)
25
µs
8
µs
1
µs
1
µs
1
µs
1. The primary coil current value Icl must be measured 1 ms after desaturation of the power stage.
2. Vd - Vbe(on).