STM6905
DC and AC parameters
Symbol
Alter-
native
Table 4. DC and AC characteristics (continued)
Description
Test condition(1)
Min
Typ
Max Unit
VHYST
tRD
Reset threshold
hysteresis
VCC to RST delay
tREC
tRP RST time-out period
Referenced to VRST1/VRST2
typical
0.5
%
VCC = (VRST1 + 100 mV) to
(VRST1 – 100 mV)
V2IN = (VRST2 + 75 mV) to
(VRST2 – 75 mV)
Option B(5)
Option C(5)
Option E
Option F(5)
20
20
20
30
80
120
140
210
280
420
µs
40
180
ms
280
560
Adjustable reset comparator input (V3IN, V4IN, V5IN)
VRSTIN
IRSTIN
tRSTIND
V3IN, V4IN, V5IN input
threshold
589
600
611 mV
V3IN, V4IN, V5IN input
current
V3IN, V4IN, V5IN > 0.8 V
–25
+25
nA
V3IN, V4IN, V5IN
hysteresis
3
mV
V3IN, V4IN, V5IN to
RST output delay
VRSTIN to (VRSTIN – 30 mV)
22
µs
Manual (push-button) reset input
VIL
VIH
tMLMH
MR input voltage
tMR
MR minimum pulse
width
0.7 x VCC
1
0.3 x VCC V
µs
tMLRL
tMRD MR to RST output delay
MR glitch immunity
200
ns
100
MR pull-up resistance
10
kΩ
1. Valid for ambient operating temperature: TA = –40 °C to +85 °C; VCC = 0.8 V to 5.5 V (except where noted).
2. 10 kΩ (typ) internal pull-up resistor.
3. The leakage current measured on the RST pin is tested with the reset de-asserted (output high impedance).
4. Other reset threshold voltages are offered. Minimum order quantities may apply. Contact local sales office for availability.
5. Other tREC time-out periods are offered. Minimum order quantities may apply. Contact local sales office for availability.
DocID14290 Rev 4
13/19