DC and AC parameters
7
DC and AC parameters
STM1404
This section summarizes the operating measurement conditions, and the DC and AC
characteristics of the device. The parameters in the DC and AC characteristics tables that
follow, are derived from tests performed under the measurement conditions summarized in
Table 5: Operating and AC measurement conditions. Designers should check that the
operating conditions in their circuit match the operating conditions when relying on the
quoted parameters.
Table 5. Operating and AC measurement conditions
Parameter
STM1404
Unit
VCC/VBAT supply voltage
Ambient operating temperature (TA)
Input rise and fall times
Input pulse voltages
Input and output timing ref. voltages
2.2 to 3.6
V
–40 to 85
°C
5
ns
0.2 to 0.8VCC
V
0.3 to 0.7VCC
V
Figure 24. AC testing input/output waveforms
0.8VCC
0.2VCC
Figure 25. MR timing waveform
MR
tMLRL
RST
tMLMH
trec
0.7VCC
0.3VCC
AI02568
AI09694
24/36