OPERATING CONDITIONS (Cont’d)
11.3.2 Operating Conditions with Low Voltage Detector (LVD)
Subject to general operating conditions for VDD, fOSC, and TA.
Symbol
VIT+(LVD)
VIT-(LVD)
Vhys(LVD)
Parameter
Reset release threshold
(VDD rise)
Reset generation threshold
(VDD fall)
LVD voltage threshold hysteresis
Conditions
VIT+(LVD)-VIT-(LVD)
VtPOR
VDD rise time rate 1)
tg(VDD)
Width of filtered glitches on VDD 1)
(which are not detected by the LVD)
Notes:
1. Data based on characterization results, not tested in production.
11.3.3 Auxiliary Voltage Detector (AVD) Thresholds
Subject to general operating condition for VDD, fOSC, and TA.
Symbol
VIT+(AVD)
VIT-(AVD)
Vhyst(AVD)
∆VIT-
Parameter
1⇒0 AVDF flag toggle threshold
(VDD rise)
0⇒1 AVDF flag toggle threshold
(VDD fall)
AVD voltage threshold hysteresis)
Voltage drop between AVD flag set
and LVD reset activated)
Conditions
VIT+(AVD)-VIT-(AVD)
VIT-(AVD)-VIT-(LVD)
Notes:
1. Data based on characterization results, not tested in production.
ST7MC1/ST7MC2
Min Typ Max Unit
4.0 1)
4.2
4.5
V
3.8
4.0 4.25
200
mV
20
µs/V
100 ms/V
40
ns
Min Typ
4.4 1)
4.7
4.2 1)
4.5
Max
4.9 1)
4.7 1)
Unit
V
200
mV
450
mV
247/294