POWER MANAGEMENT
Using the I2C Serial Port (Cont.)
Stop-Separated Reads
Stop-separated reads can also be used. This format allows a master to set up the register address pointer for a read
and return to that slave at a later time to read the data. In this format the slave address followed by a write command
are sent after a start [S] condition. The SC905A then acknowledges it is being addressed, and the master responds
with the 8-bit register address. The master sends a stop or restart condition and may then address another slave. After
performing other tasks, the master can send a start or restart condition to the SC905A with a read command. The
SC905A acknowledges this request and returns the data from the register location that had previously been set up.
I2C Stop Separated Format- Read
Register Address Setup Access
Master Addresses
other Slaves
S Slave Address W A Register Address A P S Slave Address B
Register Read Access
S/Sr Slave Address A R A Data
NACK P
S: Start Condition
W: Write = ‘0’
R: Read = ‘1’
A: Acknowledge (sent by slave)
NACK: Non-Acknowledge (sent by master)
Sr: Repeated Start Condition
P: Stop condition
Slave Address: 7-bit
Register Address: 8-bit
Data: 8-bit